Does PGA external stenting reduce compliance mismatch in venous grafts?

نویسندگان

  • Zhong-zhao Teng
  • Guang-yu Ji
  • Hong-jun Chu
  • Zhi-Yong Li
  • Liang-jian Zou
  • Zhi-yun Xu
  • Sheng-dong Huang
چکیده

BACKGROUND Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. METHODS In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA) fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. RESULTS The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. CONCLUSION The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery while remodeling develops. For the geometric mismatch, it reduces the cross-section area, therefore matching with the host artery much better. Although there are some positive effects, conclusively the PGA is not an ideal material for external stent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inhibition of accelerated atherosclerosis in vein grafts by placement of external stent in apoE*3-Leiden transgenic mice.

OBJECTIVE Vein grafts fail because of the development of intimal hyperplasia and accelerated atherosclerosis. Placement of an external stent around vein grafts resulted in an inhibition of intimal hyperplasia in several animal studies. Here, we assess the effects of external stenting on accelerated atherosclerosis in early vein grafts in carotid arteries in hypercholesterolemic apolipoprotein E...

متن کامل

Percutaneous transluminal renal angioplasty with stenting for stenotic venous bypass grafts: report of two cases

Cases of percutaneous transluminal renal angioplasty for renal artery stenosis are increasing. However, percutaneous transluminal renal angioplasty with stenting for stenotic venous bypass grafts has never been reported. Herein, the authors describe two cases of percutaneous transluminal renal angioplasty with stenting for a stenotic venous bypass graft. The patients in both cases had undergone...

متن کامل

Tissue engineering of small diameter vascular grafts.

Tissue engineering, using either polymer or biological based scaffolds, represents the newest approach to overcoming limitations of small diameter prosthetic vascular grafts. Their disadvantages include thromboembolism and thrombosis, anticoagulant related haemorrhage, compliance mismatch, neointimal hyperplasia, as well as aneurysm formation. This current review represents an overview about pr...

متن کامل

An Early Study on the Mechanisms that Allow Tissue-Engineered Vascular Grafts to Resist Intimal Hyperplasia

Intimal hyperplasia is one of the prominent failure mechanisms for arteriovenous fistulas and arteriovenous access grafts. Human tissue-engineered vascular grafts (TEVGs) were implanted as arteriovenous grafts in a novel baboon model. Ultrasound was used to monitor flow rates and vascular diameters throughout the study. Intimal hyperplasia in the outflow vein of TEVGs was assessed at the anasto...

متن کامل

Knitted nitinol represents a new generation of constrictive external vein graft meshes.

OBJECTIVE Constriction of vein grafts with braided external nitinol meshes had previously led to the successful elimination of neointimal tissue formation. We investigated whether pulse compliance, smaller kink-free bending radius, and milder medial atrophy can be achieved by knitting the meshes rather than braiding, without losing the suppressive effect on intimal hyperplasia. METHODS Pulse ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2007