Interlaboratory comparison of real-time PCR protocols for quantification of general fecal indicator bacteria.

نویسندگان

  • Orin C Shanks
  • Mano Sivaganesan
  • Lindsay Peed
  • Catherine A Kelty
  • A Denene Blackwood
  • Monica R Greene
  • Rachel T Noble
  • Rebecca N Bushon
  • Erin A Stelzer
  • Julie Kinzelman
  • Tamara Anan'eva
  • Christopher Sinigalliano
  • David Wanless
  • John Griffith
  • Yiping Cao
  • Steve Weisberg
  • Valarie J Harwood
  • Christopher Staley
  • Kevin H Oshima
  • Manju Varma
  • Richard A Haugland
چکیده

The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time PCR quantification of human adenoviruses in urban rivers indicates genome prevalence but low infectivity.

Real-time PCR was applied to quantify the abundance of human adenoviruses in two southern California urban rivers, the San Gabriel and Los Angeles. A total of 114 river samples from five different locations were collected over a 1-year period and analyzed for human adenoviruses, along with fecal indicator bacteria and coliphages. Adenoviruses were detected by real-time PCR in approximately 16% ...

متن کامل

Investigating the number of Lactobaccilus, Escherichia coli and Prevotella in fecal microbiota of adenomatous polyposis and colorectal cancer patients

Background: Colorectal cancer is the second most common cancer in the world which is mainly caused by epigenetic and environmental factors. Among these epigenetic factors, gut microbiota is an important one. Although it has not been proved a unique group of bacteria correlated with colorectal cancer, these findings have generally demonstrated differences between healthy and disease gut microbio...

متن کامل

Quantification of enterococci and human adenoviruses in environmental samples by real-time PCR.

Pathogenic bacteria and enteric viruses can be introduced into the environment via human waste discharge. Methods for rapid detection and quantification of human viruses and fecal indicator bacteria in water are urgently needed to prevent human exposure to pathogens through drinking and recreational waters. Here we describe the development of two real-time PCR methods to detect and quantify hum...

متن کامل

مقایسه روش Real-time PCR با استفاده از پرایمر همگانی 23s rRNA و روش کشت خون در تشخیص سپتی‌سمی

Background: Bloodstream infections (BSI) have a high incidence and high mortality in the worldwide. The mortality rate is variable between 20-70%. Therefore, early and timely detection of BSI agent in clinical laboratories is necessary. The aim of this study was to determine an efficient diagnostic tool to septicemia in accompany of blood culture method by Real-time PCR (using panbacterial 23S ...

متن کامل

Comparison of the multiple-sample means with composite sample results for fecal indicator bacteria by quantitative PCR and culture.

Few studies have addressed the efficacy of composite sampling for measuring indicator bacteria by quantitative PCR (qPCR). We compared results from composited samples with multiple-sample means for culture- and qPCR-based water quality monitoring. Results from composited samples for both methods were similarly correlated to multiple-sample means and predicted criteria exceedances equally.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Environmental science & technology

دوره 46 2  شماره 