Misleading behavior of Masimo pulse oximeter tone during profound bradycardia.

نویسندگان

  • Ryan E R Forde
  • Frederic M DeBros
  • Emily L Guimaraes
  • Warren S Sandberg
چکیده

bronchoscopy for removal (if detected immediately) or leading to a significant range of complications, such as segmental atelectasis, obstructive emphysema, pneumonia, or even perforation. After the detection of the problem, all blades at our institution were inspected, but none was found to have the same defect. Although this seems to be a rare finding, it is recommended to check the integrity of the laryngoscope blade on a regular basis. A quick inspection with manual pulling on the tip may help to prevent serious complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"Motion-resistant" pulse oximetry: a comparison of new and old models.

Several pulse oximeter manufacturers have recently developed instruments that are claimed to be resistant to the effects of patient motion. We performed a laboratory volunteer experiment to compare the performances of several of these instruments, as well as some older models, during combinations of motion and hypoxemia. Twenty oximeters were studied. A motorized table produced different hand m...

متن کامل

The effects of motion on the performance of pulse oximeters in volunteers (revised publication).

BACKGROUND Pulse oximetry is considered a standard of care in both the operating room and the postanesthetic care unit, and it is widely used in all critical care settings. Pulse oximeters may fail to provide valid SpO2 data in various situations that produce low signal-to-noise ratio. Motion artifact is a common cause of oximeter failure and loss of accuracy. This study compares the accuracy a...

متن کامل

Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room.

The frequency and nature of spurious pulse oximetry readings were compared using both a conventional pulse oximeter (CPO) and a prototype Masimo signal extraction technology pulse oximeter (Masimo SET). At a university hospital, 50 ASA physical status I-IV adult patients who underwent general or spinal-epidural anesthesia were selected from a group of 250 patients on the basis of high-alarm gen...

متن کامل

Accuracy of Pulse Oximeters in Detecting Hypoxemia in Patients with Chronic Thromboembolic Pulmonary Hypertension

PURPOSE Pulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2). When oxygen saturation by pulse oximeter (SpO2) overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who spent their daily lives in a poor oxyg...

متن کامل

Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 107 6  شماره 

صفحات  -

تاریخ انتشار 2007