Determination of the total arsenic concentration in human urine by inductively coupled plasma mass spectrometry: a comparison of the accuracy of three analytical methods.
نویسندگان
چکیده
Measurement of arsenic (As) in biological samples such as urine has important clinical applications and is being undertaken more frequently in epidemiologic studies because of concern about the carcinogenicity of low to moderate levels of As exposure. The objective of this study was to evaluate and improve the accuracy of As determination in urine by inductively coupled plasma mass spectrometry (ICP-MS). Determination of As in biological samples by ICP-MS is difficult for two reasons: the formation of the molecular ion 40Ar35Cl, which overlaps with monoisotopic As at a mass-to-charge ratio (m/z) of 75 (causing spectral interference), and signal enhancement due to organic matrix (nonspectral interference). Available procedures were examined, including the application of different correction procedures using 40Ar37Cl and 16O35Cl molecular-ion formation; the addition of N2 into plasma or nebulizer gas flows; and the addition of organic molecules to the sample and to calibration standards to eliminate or correct for interference due to molecular-ion formation. The accuracy and precision of determination of As [m/z 75, ionization potential (IP) 9.81 eV] with use of an internal standard was also investigated. Three elements were studied as candidate internal standards: germanium (Ge: m/z 74, IP 7.90 eV), indium (In: m/z 115, IP 5.79 eV), and tellurium (Te: m/z 128, IP 9.01 eV). It was found that these three elements performed more or less equally well with Ar-N2 plasma; it was also found that accuracy was significantly improved when Te was used as the internal standard instead of Ge or In for ethanol-added samples. Our results indicate that accurate and precise measurement of As in urine by ICP-MS can be obtained by either of two methods (< 5% error, approximately 2% RSD, limit of detection 0.1 ng ml-1): (1) the addition of 1% N2 to plasma gas flow or 3% N2 to nebulizer gas flow, along with use of any of the internal standards tested, or (2) the addition of ethanol to the sample and to calibration standards, with use of Te as the internal standard. The most accurate results (< 1% error) for National Institute of Standard and Technology Standard Reference Material (NIST SRM) 2670 (toxic elements in urine) were obtained with Ar-N2 plasma with either Te or In as the internal standard.
منابع مشابه
Development and application of a robust speciation method for determination of six arsenic compounds present in human urine.
Six arsenic species [arsenate, arsenite, arsenocholine, arsenobetaine, monomethyl arsonic acid, and dimethyl arsinic acid] present in human urine were determined using ion-exchange chromatography combined with inductively coupled plasma mass spectrometry (IC-ICP-MS). Baseline separation was achieved for all six species as well as for the internal standard (potassium hexahydroxy antimonate V) in...
متن کاملDirect Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry
The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method....
متن کاملMethods for the separation and quantification of arsenic species in SRM 2669: arsenic species in frozen human urine.
Two independent liquid chromatography inductively coupled plasma-mass spectrometry (LC/ICP-MS) methods for the separation of arsenic species in urine have been developed with quantification by standard additions. Seven arsenic species have been quantified in a new NIST frozen human urine Standard Reference Material (SRM) 2669 Arsenic Species in Frozen Human Urine, Levels 1 and 2. The species me...
متن کاملDevelopment of an analytical method for the determination of arsenic in urine by gas chromatography-mass spectrometry for biological monitoring of exposure to inorganic arsenic.
OBJECTIVES The purpose of this study was to develop an analytical method for the simultaneous determination of inorganic arsenic [As(III) and As(V)] and monomethylarsonic acid (MMA) in urine by gas chromatography-mass spectrometry (GC-MS) for the biological monitoring of exposure to inorganic arsenic. METHODS Arsenic compounds (after reduction of arsenic to the trivalent state) were derivatiz...
متن کاملDetermination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 123 3 شماره
صفحات -
تاریخ انتشار 1998