Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up.
نویسندگان
چکیده
We reviewed 100 cemented Endo-model rotating-hinge (Waldemar Link GMBH & Co, Hamburg, Germany) total knee replacements in 80 patients with a mean age of 70 years (56 to 85) at a mean post-operative follow-up of 11 years (7 to 15). Good or excellent results were seen in 91% of knees and survival at 15 years was 96.1%. There were two deep infections, one dislocation and one supracondylar fracture. There were no peri-operative deaths and there was no loosening, malalignment, migration or wear. We consider this prosthesis to be ideally suited for the replacement of the deformed knee when the use of an unconstrained design may be questionable.
منابع مشابه
Rotating Hinge Total Knee Arthroplasty RT-PLUS Solution: A Clinical and Radiographic Follow-Up
Background: In total knee arthroplasty (TKA), there is still controversy surrounding the preferable prosthetic design and required amount of constraint. Indication for rotating hinge TKA includes primary and revision arthroplasty, with contradictory results. We present the first mediumto long-term results with the rotating hinge knee prosthesis RT-PLUS SOLUTION (Smith & Nephew Orthopaedics, Baa...
متن کاملThe long-term results of endoprosthetic replacement of the proximal tibia for bone tumours.
We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and 'servicing' procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a ro...
متن کاملEndoprosthetic replacement of the distal femur for bone tumours: long-term results.
We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and 'servicing' procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 ha...
متن کاملResults with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty.
Rotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthr...
متن کاملMidterm Results of a New Rotating Hinge Knee Implant: A 5-Year Follow-Up
Background In the current study, we investigated midterm results of a new rotating hinge total knee arthroplasty (EnduRo prosthesis), which uses a new bearing material (CFR PEEK). Methods We prospectively analysed data of 50 patients with a minimum follow-up of 5 years. In 24 (48%) patients, a primary implantation was performed and 26 (52%) were revision cases. Clinical and radiographic exami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 86 6 شماره
صفحات -
تاریخ انتشار 2004