Radiography of Welds Using Selenium 75, Ir 192 and X-rays

نویسنده

  • Peter Hayward
چکیده

The selection and use of any method to be used for radiography depends on a number of considerations, these in general being: a) The size, shape, orientation and distribution of imperfection in the weld. b) The dimensions, geometry and physical properties of the weld and material. c) The radiographic sensitivity required by the Standard, Code or Specification. d) Cost of radiography. e) The location where the radiography will be carried out. f) When Se 75 can be used to replace X-ray. Radiography is suitable for the detection of volume-type flaws. Under assured circumstances it is also suitable for the detection of lack of fusion, cracks and crack-like planar flaws which are oriented in the direction of the radiation beam; however, however it needs to be remembered that the ability of radiography to detect such planar flaws diminishes with unfavourable orientation. The successful use of radiography depends on the ability of the radiation source, be it x-ray or gamma, to provide sufficient radiation to penetrate the material and produce an image of acceptable contrast and definition on the processed radiographic film, using an acceptable and economic time. This paper presents the results of various techniques used on selected samples. These samples used contained a variety of flaws. The samples were subjected to radiographic inspection using X-rays, Ir 192 and Se 75 and the use of different classes of film.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioprotective effects of selenium and vitamin-E against 6MV X-rays in human blood lymphocytes by micronucleus assay

Background: Critical macromolecules of cells such as DNA are in exposure to damage of free radicals that induced from the interaction of ionizing radiation with biological systems. Selenium and vitamin-E are natural compounds that have been shown to be a direct free radical scavenger. The aim of this study was to investigate the radioprotective effect of selenium and vitamin-E separately and sy...

متن کامل

A COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL

 ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...

متن کامل

Achieving greater efficiency in NDT inspections

Describes the application of an ultrasonic sensing system for the non-destructive inspection of welds as an alternative to X-rays. Replacing radiography with ultrasound not only allows faster, more economical inspections but also eliminates the health and safety risks associated with radiography. In practical terms that means there is no need to evacuate the site for inspection purposes ± const...

متن کامل

The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography

Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...

متن کامل

Performance Characterization of Amorphous Silicon Digital Detector Arrays for Gamma Radiography

This paper reports the performance characteristics of a-Si detectors with Ir-192 gamma source. Imaging performance of the detector system is evaluated using contrast sensitivity over a range of material thickness of steel, signal to noise ratio, dynamic range and linearity. The radiographic sensitivity was observed over a range of thickness of steel using standard image quality indicators. Quan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006