Rescanning to mitigate the impact of motion in scanned particle therapy
نویسندگان
چکیده
Treatment of targets that move during the irradiation with a scanned particle beam leads to deterioration of the dose distribution [1]. This dose deterioration results from interference of target motion and scanned beam, so called interplay. Apart from beam tracking [2] and gating [3] rescanning [4] can be used to mitigate the impact of motion. Rescanning mitigates interplay effects by multiple reirradiations of the target with proportionally less dose during a single scan and margins that cover the motion extent. In principle, local mis-dosage averages out over several reirradiations. Rescanning was implemented at GSI, initial results are presented.
منابع مشابه
Dosimetric Studies for Rescanning in scanned particle therapy*
Treatment of moving targets can result in local over and under dosage due to interference effects of the beam application and the motion of the target, so called interplay. Rescanning is one option to mitigate effects of tumor motion in scanned particle therapy [1, 2]. Rescanning is based on statistical methods that show that the dosimetric effect of interplay will average and lead to a homogen...
متن کامل4D treatment (planning) workshop
no 1: Technical challenges of fast volumetric rescanning O. Actis, D. Meer, A. Mayor, G. Klimpki, S. Psoroulas, D.C. Weber For pencil beam scanning the most studied method to mitigate the dose delivery uncertainties due to the organ motion is rescanning. Achieving an optimal treatment for a moving target by volumetric rescanning, where the whole tumour volume is scanned multiple times, requires...
متن کاملTreatment planning study: Motion mitigation techniques for lung tumors
Introduction Currently, the C-12 therapy performed at GSI cannot be applied to moving tumors because interplay between scanned ion beam and moving target does not allow controlled dose delivery. Several techniques are proposed to mitigate the influence of interplay. Among them are tracking [1], gating [2], rescanning [3], and use of margins. We used the 4D extension of GSI’s treatment planning ...
متن کاملComparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.
In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the treatment of mobile targets with these techniques. Of different motion mitigati...
متن کاملMotion compensation with a scanned ion beam: a technical feasibility study
BACKGROUND Intrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam. METHODS Lateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal ...