Evaluation of lumbar spine motion with dynamic X-ray--a reliability analysis.
نویسندگان
چکیده
STUDY DESIGN Radiologic evaluation of lumbar range of motion (ROM) with dynamic radiograph. OBJECTIVES To calculate 95% confidence intervals (CIs) for the measurement error accompanying different methods, different observers, and different levels of training when measuring sagittal plane segmental ROM in lumbar spine. In addition, to compare the 95% CI with frequently common statistical methods of reliability analysis. SUMMARY OF BACKGROUND DATA Dynamic radiographs are commonly used for ROM calculation of the lumbar spine. Yet, the reliability of different measurement methods still remains unclear. METHODS In 24 patients, levels L4-L5 and L5-S1 were measured with the Cobb and superimposition methods on flexion-extension radiographs. There were 2 experienced and 1 inexperienced observer that performed the measurements. The 95% CIs were compared with the corresponding Pearson correlation coefficient and P value (t test). RESULTS The 95% CI of the superimposition method was +/-4.0 degrees for the experienced and +/-4.7 degrees for the inexperienced observer. The corresponding values for the Cobb method was +/-4.2 degrees for the experienced and +/-6.8 degrees for the inexperienced observer. The 95% CI for the measurement error became even worse when different methods or observers were compared, whereas a method constancy revealed superior reliability than observer constancy in experienced observers. CONCLUSIONS For lumbar ROM measurement with dynamic radiograph, the superimposition method seems to be more reliable than the Cobb method. Study protocols dealing with ROM measurement have to calculate the 95% CI of the measurement method used because clinically valid conclusions can only be drawn with respect to these intervals.
منابع مشابه
The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients
Purpose: Regarding the high prevalence of low back pain in various communities and the need to determine an appropriate treatment plan for these patients, examining their functional limitation and disability level is of utmost importance. In this regard, one of the important indicators is Lumbar range of motion. Measurement of the range of motion is a common and appropriate method for determini...
متن کاملEvaluation of bone mineral density in long-term survivors of childhood acute lymphoblastic leukemia
Background: The purpose of this study was to evaluate long-term changes in bone density profile among survivors of childhood acute lymphoblastic leukemia. Patients and Methods: This was a 5 year prospective study comprised of thirty-one survivors of childhood acute lymphoblastic leukemia with a mean age of 11.8 (4.6) years, who completed therapy at least 1 year previously (according to the ...
متن کاملA new technique for digital fluoroscopic video assessment of sagittal plane lumbar spine motion.
STUDY DESIGN Methodological reliability. OBJECTIVE Develop a measurement technique to assess dynamic motion of the lumbar spine using enhanced digital fluoroscopic video (DFV) and a distortion compensated roentgen analysis (DCRA). SUMMARY OF BACKGROUND DATA Controversy over both the definition and consequences of lumbar segmental instability persists. Information from static imaging has had...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملThe reliability of the CODA motion analysis system for lumbar spine analysis: a pilot study
Background: Low bock pain (LBP)is 0 very common musculoskeletal disorder. Lumbar range of motion (ROM) and posture are parameters which are commonly assessed in LBP research. Reliable methods of measuring lumbar spine ROM and posture are needed. The CODA motion analysis system has several potential advantages over other motion analysis systems; however its reliability for lumbar spine analysis ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Spine
دوره 31 11 شماره
صفحات -
تاریخ انتشار 2006