Thermal monitoring and indoor temperature predictions in a passive solar building in an arid environment
نویسندگان
چکیده
In this paper, results of a long-term temperature monitoring in a passive solar house, located at the Sede-Boqer Campus of the BenGurion University, in the Negev region of Israel are presented. Local latitude is 30.81N and the elevation is approximately 480m above sea level. The climate of the region is characterized by strong daily and seasonal thermal fluctuations, dry air and clear skies with intense solar radiation. The monitored building consists of a two storey, passive solar house and belongs to a student dormitory complex located at the Sede-Boqer Campus. Formulae were developed, based on part of the whole monitoring period, representing the measured daily indoor maximum, average and minimum temperatures. The formulae were then validated against measurements taken independently in different time periods. In managing the building, the main objective in the winter was to bring up the indoor temperature by direct and indirect solar gains while in the summer it was to keep the temperature down. Therefore, analysis of the data and development of predictive formulas of the indoor temperatures were done separately for the winter and for the summer. Measured data of each season were then divided into two sub-periods, the first one used to generate formulas based on measured data (generation) and the second for testing the predictability of the formulas by independent data (validation). In general, a fairly good agreement was verified between onsite measurements and results of the formulae, with regard to daily indoor maximum, average and minimum temperatures. The issue of using outdoor temperatures measured in the adjacent street canyon instead of those registered at the local meteorological site for evaluating the building’s cooling demand is also addressed in the paper. The developed formulae were here used for estimating the building’s thermal and energy performance in summer, taking into account: (1) solely climatic data from the meteorological station; (2) climatic data from the meteorological station, except for outdoor ambient temperature, which was monitored adjacent to building. Results indicated that the calculation of the building’s energy demand for air-conditioning based on temperature data collected at the meteorological station would yield half of the cooling degree-days externally and about two-thirds of that internally, as compared to adopting measured canyon temperatures for such calculations. r 2007 Elsevier Ltd. All rights reserved.
منابع مشابه
Glazed Transitional Space as a Passive Heating System (Case Study: Glazed Loggias in Semi-Arid climate)
The environmental concern, ensuring comfort for occupants, pushed us to search for the impact of glazed loggia on thermal comfort of adjacent space in Cons tantine climate, having s trong climatic cons traints. An experimental s tudy is undertaken and described in this paper. Analysis of the in situ results is also discussed. This work shows that in winter glazed loggia benefit largely from sol...
متن کاملبهسازی حرارتی جدار ساختمانهای موجود در اقلیم سرد در ایران با بهرهگیری از ویژگیهای دیوار ترومب
This research is aimed to find an energy optimization method for existing buildings in cold climate regions of Iran. In the proposed system, a secondary skin is installed against the unglazed surfaces of the southern wall, creating a Trombe-wall. The sun-facing wall is then painted in black, and covered with a transparent material like clear glass, leaving a closed air gap between them. The res...
متن کاملPerformance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)
In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...
متن کاملField Measurement and Evaluation of the Passive and Active Solar Heating Systems for Residential Building Based on the Qinghai-Tibetan Plateau Case
Passive and active solar heating systems have drawn much attention and are widely used in residence buildings in the Qinghai-Tibetan plateau due to its high radiation intensity. In fact, there is still lack of quantitative evaluation of the passive and active heating effect, especially for residential building in the Qinghai-Tibetan plateau areas. In this study, three kinds of heating strategie...
متن کاملThermal Behavior of Double Skin Facade in Terms of Energy Consumption in the Climate of North of Iran-Rasht
Industrialization and increasing demand for the consumption of fossil fuels cause that energy becomes a strategic factor. Energy crisis and the emergence of modern architecture led designers to pay more attention to the important task of building's envelope. Building skins play an important role in building thermal behavior and reduce energy consumption. If Double Skin Facades properly designed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -