Minimally invasive force sensing for tendon-driven robots

نویسندگان

  • Alberto Cavallo
  • Giuseppe De Maria
  • Ciro Natale
  • Salvatore Pirozzi
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally Invasive Repair of Acute Achilles Tendon Rupture Using Gift Box Technique

Background: This study aimed to introduce a modified technique for minimally invasive Achilles tendon (AT) rupture repairusing gift box sutures. The preliminary clinical and functional outcomes were investigated among a number of patients.Methods: In a consecutive case series study, 24 patients with acute AT rupture underwent modified minimally invasiveAT repair using two mini...

متن کامل

Design, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force

This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...

متن کامل

Minimally invasive repair of ruptured Achilles tendon.

OBJECTIVE To study the clinical outcomes of minimally invasive repair of ruptured Achilles tendon. DESIGN Retrospective study. SETTING Orthopaedics and Traumatology Department of a public hospital in Hong Kong. PATIENTS Fifteen consecutive patients admitted to the hospital from August 2002 to April 2005 with closed Achilles tendon rupture, had it repaired by a minimally invasive method. P...

متن کامل

A Novel Tele-Operated Flexible Robot Targeted for Minimally Invasive Robotic Surgery

In this paper, a novel flexible robot system with a constrained tendon-driven serpentine manipulator (CTSM) is presented. The CTSM gives the robot a larger workspace, more dexterous manipulation, and controllable stiffness compared with the da Vinci surgical robot and traditional flexible robots. The robot is tele-operated using the Novint Falcon haptic device. Two control modes are implemented...

متن کامل

A Three-Dimensional Shape-Based Force and Stiffness-Sensing Platform for Tendon-Driven Catheters

This paper presents an efficient shape-based three-axial force and stiffness estimator for active catheters commonly implemented in cardiac ablation. The force-sensing capability provides important feedback for catheterization procedures including real-time control and catheter steering in autonomous navigation systems. The proposed platform is based on the introduced accurate and computational...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009