New design in anterior chamber lenses.
نویسنده
چکیده
MoiE and more attention is being paid to the question of intra-ocular acrylic implants since Ridley's original venture into this field. More recently, interest has changed from Ridley's original idea of an acrylic lens replacing the extracted lens in position behind the pupil to the anterior chamber implant. It is possible that this has happened because of the greater ease of insertion of the anterior chamber lenticulus and the fact that it is easier to take such a lens out should anything go wrong; furthermore, the anterior chamber lens has the great advantage over Ridley's lens of being capable of insertion after an intra-capsular operation or a cataract extraction with full iridectomy or both. The best known of the anterior chamber lenses in use at present is the Strampelli lens, which is made entirely in plastic; the shape being approximately as shown in Fig. 1.
منابع مشابه
Scanning electron microscopic characteristics of phakic intraocular lenses.
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from ...
متن کاملBilateral anterior chamber intraocular lenses dislocation in a patient with habitual eye rubbing.
A 61-year-old Chinese man presented with bilateral posteriorly dislocated anterior chamber intraocular lenses (AC IOLs) one year after successful vitrectomy, removal of bilateral dislocated mature cataractous lenses and AC IOLs implantation. A thorough clinical evaluation revealed habitual eye rubbing as the only possible cause.
متن کاملExperience with Twelve Cases of Intra-ocular Anterior Chamber Implants for Aphakia: Two New Models of Lenses Are Described.
UNIOCULAR aphakia is a condition of artificial anisometropia which very often causes great annoyance to the sufferer, who finds the aphakic eye of little use if the other eye is normal, and often complains of lack of binocular function and difficulty in judging distances, especially at close range. If contact lenses have been tried with unsatisfactoryresults, it seems justifiable especially in ...
متن کاملPosterior dislocation of an intraocular lens implant and its removal.
The cause of dislocation of an intraocular lens is a direct blow or jerk, and dislocation may complicate both iris-supported and capsule-supported lenses. In capsule-supported lenses the implant dislocates towards the anterior chamber but in iris-supported lenses the dislocation is posterior. A technique for removal of a posterity dislocated lens is described.
متن کاملManagement of absent capsular support with a new Intraocular Lens design
Purpose: To describe a new intraocular lens that can be implanted in case of rupture of the posterior capsule and lack of capsular support. Methods: This experimental study was carried out on ten Flanders rabbits. The right eye of each rabbit underwent intra capsular lens extraction and two peripheral iridectomies, and the new lens was implanted with an optic rest in the posterior chamber. Addi...