Lung deposition of aerosol--a comparison of different spacers.

نویسندگان

  • H J Zar
  • E G Weinberg
  • H J Binns
  • F Gallie
  • M D Mann
چکیده

AIMS To investigate (1) aerosol lung deposition obtained from two small volume conventional spacers (Babyhaler and Aerochamber) and a home made spacer (modified 500 ml plastic cold drink bottle); (2) the effect of using a face mask or mouthpiece; and (3) the relation between age and pulmonary deposition. METHODS Lung deposition of aerosolised technetium-99m DTPA inhaled via spacer was measured in 40 children aged 3-7 years with stable asthma. Each patient performed sequential randomly assigned inhalations using two spacers. Three studies were performed: Babyhaler compared to Aerochamber (with facemasks); Babyhaler with facemask compared to Babyhaler with mouthpiece; and Babyhaler with mouthpiece compared to a 500 ml bottle. RESULTS Median lung aerosol deposition from a Babyhaler and Aerochamber with masks were similar (25% v 21%, p = 0.9). Aerosol lung deposition from a Babyhaler with mask compared to a Babyhaler with mouthpiece was equivalent (26% v 26%, p = 0.5). Lung deposition was higher from a 500 ml bottle compared to a Babyhaler in both young (25% v 12.5%, p = 0.005) and older children (42% v 22.5%, p = 0.003). A notable reduction in pulmonary deposition occurred at 50 months of age. CONCLUSION A Babyhaler or Aerochamber produce equivalent lung deposition of aerosol. There is no difference in lung deposition when a mask or mouthpiece is used. A modified 500 ml plastic bottle produces greater pulmonary aerosol deposition than a conventional small volume spacer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

متن کامل

[Evaluation of the influence of patient age and spacer device volume on aerosol lung deposition].

OBJECTIVE To evaluate the efficacy of three frequently used spacer devices to deliver aerosol to the lung, and to compare radioaerosol deposition with each device in different age groups. METHODS Nine healthy, non-smoking volunteers were recruited: three adults and six children, including three toddlers and three school age children. Qualitative and semi-quantitative analysis of radioaerosol ...

متن کامل

Numerical Study of Heat Transfer and Aerosol Deposition in a Room Environment with Under-floor or Baseboard Heating Systems

In this study, heat transfer and aerosol deposition in the under-floor and baseboard heating systems have been investigated, numerically. The aim of this study is a comparison between these heating systems. This comparison obtains the optimal heating system with low suspended particles in the air. Computational fluid dynamic with Eulerian-Lagrangian method has been used to simulate fluid and pa...

متن کامل

Aerosol delivery of ferulic acid-loaded nanostructured lipid carriers: A promising treatment approach against the respiratory disorders

Introduction: Treatment of lung diseases is one of the major healthcare challenges. Ferulic acid (FA), a phenolic compound with well-established antioxidant and anti-inflammatory properties, has shown promising therapeutic potential against the pulmonary disorders; however, low bioavailability may negatively affect its efficiency. This, prompted us to incorporate FA into the nanostructured ...

متن کامل

Computational analyses of a pressurized metered dose inhaler and a new drug-aerosol targeting methodology.

The popular pressurized metered dose inhaler (pMDI), especially for asthma treatment, has undergone various changes in terms of propellant use and valve design. Most significant are the choice of hydrofluoroalkane-134a (HFA-134a) as a new propellant (rather than chlorofluorocarbon, CFC), a smaller exit nozzle diameter and attachment of a spacer in order to reduce ultimately droplet size and spr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 82 6  شماره 

صفحات  -

تاریخ انتشار 2000