Importance of transducer displacement and tilting on three-dimensional echocardiographic volume assessment using apical or off-axis rotational acquisition: an in vitro study.
نویسندگان
چکیده
OBJECTIVE The goal of this study was to assess effects of translation (horizontal displacement) and angulation (transducer tilting) on 3-dimensional (3D) echocardiographic volumes of both balloons and human left ventricles after autopsy. METHODS Six water-filled (non-) aneurysmatic balloons of 150, 250, and 350 mL and 3 hearts of different sizes and shapes were suspended upright in a water bath. Angulation and/or translation was performed respectively by tilting the transducer with a mechanical arm in a vertical plane relative to the balloon tip or true apex of the hearts and by shifting the water bath in the same vertical plane. For balloon and left ventricular (LV) volume assessment, a 3D conical data set was obtained by TomTec rotational acquisition in combination with a HP Sonos 5500 ultrasound machine. RESULTS For the 6 balloons, translation from 1 to 4 cm yielded volumes of up to 74% of the optimal volume (100%); angulation of 10 degrees or 20 degrees, volumes of up to 80% and 34%. Translation with 10-degree angulation yielded volumes up to 64%; for 20-degree angulation and translation, there was no volume loss. Results were similar for the left ventricles. CONCLUSIONS Even minor angulation or translation of the transducer yields substantial underestimation of the true volume. Off-axis para-apical views, however, defined as angulation of 20 degrees and greater than 0.5 cm translation in this in vitro model, obviate volume underestimation. Such views in patients, if obtainable, may be an attractive alternative for conventional apical 3D acquisition, especially in dilated and aneurysmatic hearts.
منابع مشابه
Effect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملIn vitro two-dimensional echocardiographic imaging of a stented porcine bioprosthetic valve: the bent strut artifact.
BACKGROUND Echocardiographic imaging of a stented valve bioprosthesis can reveal apparent inward deflection of one or more struts. It could be assumed that this finding is related to actual strut distortion as opposed to an artifact of off-axis imaging. OBJECTIVE To determine whether normal (nondistorted) bioprosthetic struts can appear by artifact to be bent inward on two-dimensional echocar...
متن کاملLeft ventricular volume calculations using a multiplanar transoesophageal echoprobe; in vitro validation and comparison with biplane angiography.
BACKGROUND Biplane angiographic and transthoracic echocardiographic volume calculations have shown to be sufficiently reliable in symmetric hearts; however, they are unreliable in the presence of aneurysmatic distortions. Multiplane transoesophageal echocardiography offers unobstructed cross-sectional views of the heart from one stable transducer position with the potential of imaging irregular...
متن کاملRapid three-dimensional echocardiography : clinically feasible alternative for precise and accurate measurement of left ventricular volumes.
BACKGROUND Clinical applicability of conventional ultrasonographic systems using mechanical adapters for 3D echocardiographic imaging has been limited by long acquisition and processing times. We developed a rapid (6-s) acquisition technique that collects apical tomograms using a continuously internally rotating transthoracic transducer. This study was performed to examine the clinical feasibil...
متن کاملThree-Dimensional Echocardiography
This brief overview relates to the recent introduction of real-time three-dimensional echocardiographic imaging techniques, which has revolutionized echocardiography, as images are obtained in just one beat. A great potential lies ahead as clinical applications are multiple. T H R E E D I M E N S I O N A L E C H O C A R D I O G R A P H Y In the past, routine clinical use of three-dimensional ec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 15 1 شماره