Evaluation of different techniques for CT radiation profile width measurement

نویسندگان

  • Steven R. Jackson
  • Salahuddin Ahmad
  • Yida Hu
  • Chun Ruan
چکیده

This work has been conducted to demonstrate a procedure for using a Konica Minolta computed radiography (CR) system for the measurement of computed tomography (CT) radiation profile width, and to compare this method with conventional and GAFCHROMIC XR-QA2 film measurements. The exposure and processing conditions of a Konica Minolta CR reader system were characterized to establish the relationship between exposure at the imaging plate (IP) and pixel value. A 6 cc ionization chamber was exposed at the isocenter of a CT scanner using 80 kVp, 0.4 sec with various mA settings. CR images were processed in fixed modes with various combinations of S and G values, establishing exposure and pixel value relationships. Appropriate exposure techniques and processing parameters were selected to avoid the saturation of the IP. Using the selected exposure and processing parameters, radiation profiles of various nominal collimation settings (40, 20, 10, and 5 mm) were acquired for measurement. Radiochromic film was characterized and utilized to compare with CR profiles and profiles obtained via conventional film. Appropriate exposures for both CR (80 kVp, large body filter, 4 and 8 mAs) and radiochromic films (120 kVp, large body filter, 300 mAs) were determined. Recommended CR processing settings (fixed mode with S = 5 and G= 1.81) were also determined. Compared to the conventional film results, the full width at half maximum (FWHM) results for CR agreed well within ± 10%, while radiochromic film results showed maximum deviations of about 5%. In conclusion, FWHM of CT radiation profiles can be conveniently and accurately measured using a Konica Minolta CR system or XR-QA2 film when appropriate exposure technique and processing parameters are used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

Measurement of organ dose in chest CT examination using Monte Carlo simulation

Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Dosimetric evaluation of a 320 detector row CT scanner unit

BACKGROUND The technologic improvements in Multislice scanners include the increment in the X-ray beam width. Some new CT scanners are equipped with a 320 detector row which allows a longitudinal coverage of 160 mm and a total of 640 slices for a single rotation. When such parameters are used the length of the traditional pencil chamber (10 cm) is no more appropriate to measure the standard wei...

متن کامل

CT radiation profile width measurement using CR imaging plate raw data

This technical note demonstrates computed tomography (CT) radiation profile measurement using computed radiography (CR) imaging plate raw data showing it is possible to perform the CT collimation width measurement using a single scan without saturating the imaging plate. Previously described methods require careful adjustments to the CR reader settings in order to avoid signal clipping in the C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013