Revision of the Charnley low-friction arthroplasty for recurrent or irreducible dislocation.
نویسندگان
چکیده
Twenty-one cases of the Charnley low-friction arthroplasty were revised because of recurrent or irreducible dislocation. Three main reasons for this revision, usually in combination, were identified: loss of the abductor mechanism due to trochanteric detachment; shortening of the limb due to high placement of the socket or low section of the femoral neck; and malorientation of the components. Sixteen patients had no further problems after revision. One patient had a single dislocation, four had more than one dislocation although they managed to cope with them and did not require a further revision.
منابع مشابه
Charnley low-friction arthroplasty: survival patterns to 38 years.
We studied survival to 38 years after Charnley low-friction arthroplasty of the hip. We used revision as an end-point, while adopting a policy of regular follow-up and early revision for radiological changes alone if indicated. Between November 1962 and June 2005, 22,066 primary low-friction arthroplasties (17,409 patients) had been performed at Wrightington Hospital by more than 330 surgeons. ...
متن کاملDegenerative Hip Joint Pain – The Non-Arthroplasty Surgical Options
Degenerative Hip Joint Pain (DHJP) is a major cause of functional limitation in both young active and old sedentary patients. Total hip arthroplasty (THA) is one of the most successful surgical procedures performed in orthopaedics. Sir John Charnley introduced the concept of low friction arthroplasty for end stage hip arthritis. The rewarding result of this procedure makes THA the gold standard...
متن کاملCharnley low-friction arthroplasty of the hip. Five to 25 years survivorship in a general hospital
BACKGROUND Some studies have raised the question about whether the good results obtained with the Charnley prosthesis could be replicated at general hospitals when it comes to the frequency of early complications and failure rates, both of which would be higher than those published by centres devoted to hip arthroplasties. METHODS We reviewed the results of 404 Low Friction Arthroplasties of ...
متن کاملThe Charnley versus the Spectron hip prosthesis: clinical evaluation of a randomized, prospective study of 2 different hip implants.
Prospective, randomized studies must be performed when new surgical techniques or implants are evaluated. In this study, a new implant system was compared with the Charnley prosthesis, which over the years has been the most used hip implant in Sweden. Between 1985 and 1989, 410 hips were randomized to treatment with a Charnley or a Spectron total hip arthroplasty: 206 Charnley and 204 Spectron ...
متن کاملThe prognosis and treatment of dislocated total hip arthroplasties with a 22 mm head.
We studied the risk of recurrent dislocation in 121 primary and 39 revision Charnley or Charnley hybrid total hip arthroplasties which had been treated for a primary dislocation between 1979 and 1995. Only 35% of these hips had no further dislocation or a revision for instability within one year. The rates of survival gradually declined with time or if a second, third or fourth dislocation occu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 63B 4 شماره
صفحات -
تاریخ انتشار 1981