Intubation with VivaSight or conventional left-sided double-lumen tubes: a randomized trial.

نویسندگان

  • Rolf Schuepbach
  • Bastian Grande
  • Giovanni Camen
  • Alexander R Schmidt
  • Henrik Fischer
  • Daniel I Sessler
  • Burkhardt Seifert
  • Donat R Spahn
  • Kurt Ruetzler
چکیده

INTRODUCTION Double-lumen endotracheal tubes (DLTs), which are commonly used for single-lung ventilation during surgery, are difficult to insert. In addition, they often move during surgical lung manipulation which can cause life-threatening complications. Flexible bronchoscopy is used routinely to establish and confirm proper DLT placement. The newly designed VivaSight DLT has an integrated camera, allowing continuous visualization of its position in the trachea. We hypothesized that the time to intubation using the VivaSight DLT would be faster than with a conventional DLT. METHODS We enrolled 40 adults scheduled for thoracic surgery. Patients were randomized to conventional DLT (n = 20) or VivaSight DLT (n = 20). Time to intubation was our primary outcome. Secondary outcomes were insertion success without flexible bronchoscopy, frequency of tube displacement, ease of insertion, quality of lung collapse, postoperative complaints, and airway injuries. RESULTS Time [mean (SD)] to successful intubation was significantly faster with the VivaSight DLT [63 (58) sec] compared with the conventional DLT [97 (84) sec; P = 0.03]. The VivaSight DLTs were correctly inserted during all attempts. When malpositioning of the VivaSight DLT occurred, it was easily remedied, even in the lateral position. The devices were comparable with respect to postoperative coughing, hoarseness, and sore throat. Airway injuries tended to be more common with the VivaSight DLT, although this study was underpowered for airway injuries. CONCLUSION The VivaSight DLT camera allowed faster insertion and facilitated initial positioning. It also confirmed proper tube positioning intraoperatively and facilitated repositioning when necessary. This trial was registered at clinicaltrials.gov: NCT01807676.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In reply. Safe and effective positioning of a left-sided double-lumen tube.

To the Editor, As discussed in our paper, positioning the VivaSight DLT 34 sec faster than positioning a conventional doublelumen tube is of marginal clinical importance. Then again, faster insertion is consistent with the fact that the tube is easy to use. Furthermore, the ability to obtain immediate assurance of at least an approximately correct position with the VivaSight camera likely facil...

متن کامل

Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?

UNLABELLED The aim of this study was to assess the performance of the ETView VivaSight SL (ETView) single-lumen airway tube with an integrated high-resolution imaging camera in a manikin-simulated cardiopulmonary resuscitation scenario with and without chest compression. This was a randomized crossover manikin trial. Following a brief training session, 107 volunteer novice physicians who were i...

متن کامل

A simple blind placement of the left-sided double-lumen tubes: Erratum

One-lung ventilation (OLV) has been commonly provided by using a double-lumen tube (DLT). Previous reports have indicated the high incidence of inappropriate DLT positioning in conventional maneuvers.After obtaining approval from the medical ethics committee of First Affiliated Hospital of Anhui Medical University and written consent from patients, 88 adult patients belonging to American societ...

متن کامل

Hemodynamic and Humoral Response to Intubation with Double-lumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial

Introduction: Insertion of endotracheal tubes, especially large and relatively inflexible double-lumen tubes, provokes cardiovascular and humoral responses which can cause complications. Bronchial blockers, combined with conventional single-lumen tubes (SLT), serve as alternatives to double-lumen tubes (DLT) and may provoke less hemodynamic response. Methods: Forty adults scheduled for elective...

متن کامل

Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques

BACKGROUND Double-lumen endobronchial tubes (DLTs) are commonly advanced into the mainstem bronchus either blindly or by fiberoptic bronchoscopic guidance. However, blind advancement may result in misplacement of left-sided DLTs into the right bronchus. Therefore, incidence, risk factors, and blind repositioning techniques for right bronchial misplacement of left-sided DLTs were investigated. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 62 7  شماره 

صفحات  -

تاریخ انتشار 2015