The laryngeal tube device: a simple and timely adjunct to airway management.
نویسندگان
چکیده
INTRODUCTION Endotracheal intubation (ETI) is a motor skill that demands practice. Emergency medical service providers with limited intubation experience should consider using airway adjuncts other than ETI for respiratory compromise. Prehospital ETI has been recently interrogated by evidence exposing worsened patient outcomes. The laryngeal tube (LT) airway was approved by the Food and Drug Administration in 2003 for use in the United States. Using difficult airway-simulated models, we sought to describe the time difference between placing the ETI and LT and the successful placement of each adjunct in varied levels of healthcare providers. METHODS Emergency medicine resident physicians, fourth year medical students, and paramedic students were asked to use both ETI and the LT. Subjects were timed (seconds) on ETI and LT placement on 2 different simulators (AirMan and SimMan; Laerdal Co, Wappingers Falls, NY). After ETI was complete, they were given 30 seconds to review an instructional card before placement of the LT. We measured placement time and successful placement of the device for ETI vs LT. Successful placement in the manikin was defined by a combination of breath sounds, chest rise, and absence of epigastric sounds. RESULTS Overall mean placement time in the AirMan and SimMan for ETI was 76.4 (95% confidence interval [CI], 63.3-89.5) and 45.9 (95% CI, 41.0-50.2) seconds, respectively. Mean placement time for the LT in the AirMan and SimMan was 26.9 (95% CI, 24.3-29.5) and 20.3 (95% CI, 18.1-22.5) seconds, respectively. The time difference between ETI and LT for both simulators was significant (P < .0001). Successful placement of the LT compared with ETI in the AirMan was significant (P = .001). CONCLUSIONS A significant time difference and simplicity exists in placing the LT, making it an attractive device for expeditious airway management. Further studies will need to validate the LT effectiveness in ventilation and oxygenation; however, its uncomplicated design allows for successful use by a variety of healthcare providers.
منابع مشابه
مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA
Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملمقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان
Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...
متن کاملمقایسه تاثیر لوله گذاری داخل نای و جاگذاری ماسک حنجره بر فشار داخل چشمی
Background and purpose: control of intraocular pressure has specific role in ophthalmic surgery but ËTT as a common access to airway in general anesthesia lead to increase in ÏÔP, so, many study have been done to evaluate an alternative access to airway such as laryngeal mask. We conducted this study to evaluate intraocular pressure changes subsequent to insertion of laryngeal mask airway and...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of emergency medicine
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2007