TAXUS VI 2-year follow-up: randomized comparison of polymer-based paclitaxel-eluting with bare metal stents for treatment of long, complex lesions.

نویسندگان

  • Eberhard Grube
  • Keith D Dawkins
  • Giulio Guagliumi
  • Adrian P Banning
  • Krzysztof Zmudka
  • Antonio Colombo
  • Leif Thuesen
  • Karl Hauptman
  • Jean Marco
  • William Wijns
  • Jeffrey J Popma
  • Lutz Buellesfeld
  • Joerg Koglin
  • Mary E Russell
چکیده

AIMS Drug-eluting stents (DESs) have shown to be effective in reducing in-stent restenosis, although data relating to long-term experience in treating more complex lesion subsets are limited. In order to assess the long-term safety and clinical efficacy of the polymer-based moderate release (MR) paclitaxel-eluting TAXUS MR stent in treatment of complex lesion subsets, we evaluated the 2-year follow-up of TAXUS VI. METHOD AND RESULTS TAXUS VI was a randomized multi-centre study enrolling 446 patients with complex lesions, including small vessels in 28% of patients and a mean lesion length of 20.6 mm. At 9-month follow-up, the use of the TAXUS MR stent was highly effective, resulting in a significant 53% reduction of the target vessel revascularization (TVR) rate (primary endpoint) from 19.4% in the control group to 9.1% in the TAXUS group (P = 0.0027). Clinical follow-up at 2 years post-stenting was available in 98.6% of the TAXUS group and 95.6% of the control group. The incidence of major adverse cardiac event at 1- and 2-year follow-up was 16.4% and 21.3% in the TAXUS group when compared with 22.5 and 25.1% in the control group, respectively. A significant difference in TVR was maintained at 2-year follow-up (TAXUS 13.9%; control 21.9%; P = 0.0335). The cumulative 1- and 2-year survival rates free from TVR were, respectively, 91.7 and 90.3% in the TAXUS group vs. 80.0 and 79.0% in the control group (log-rank P < 0.001). The number of patients required to be treated with a TAXUS stent to prevent one re-percutaneous coronary intervention at 2 years was 12.5. CONCLUSION Treatment of complex coronary lesions with the polymer-based MR paclitaxel-eluting TAXUS MR stent is associated with a sustained clinical benefit and low rates of TVR up to 2 years after device implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions.

BACKGROUND The TAXUS II trial was designed to evaluate the safety and efficacy of the commercialized slow-release (SR) and an investigation-only moderate-release (MR) polymer-based TAXUS paclitaxel-eluting stent compared with a bare-metal stent for the treatment of de novo coronary lesions. METHODS AND RESULTS This prospective, randomized, double-blind, controlled trial enrolled 536 patients ...

متن کامل

Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: support for the use of drug-eluting stents in contemporary clinical practice.

BACKGROUND Intracoronary polymer-based stent delivery of paclitaxel has been shown to be effective in reducing restenosis in simple coronary lesions, but the evidence base for contemporary use in longer, more complex coronary stenoses is lacking. METHODS AND RESULTS TAXUS VI is a prospective, multicenter, double-blind, randomized trial assessing clinical and angiographic outcomes of the TAXUS...

متن کامل

Outcomes of paclitaxel-eluting stent implantation in patients with stenosis of the left anterior descending coronary artery.

OBJECTIVES We sought to examine the efficacy of paclitaxel-eluting stent implantation in the left anterior descending coronary artery (LAD). BACKGROUND Restenosis and recurrent cardiac events after percutaneous intervention are more common for lesions in the LAD than other native coronary arteries, and often necessitate bypass surgery. Drug-eluting stents may improve the long-term prognosis o...

متن کامل

One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent

Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...

متن کامل

Two-year-plus follow-up of a paclitaxel-eluting stent in de novo coronary narrowings (TAXUS I).

Early results with polymer-based paclitaxel-eluting stents have shown significant improvements in the clinical and angiographic parameters of restenosis, as well as excellent safety outcomes. However, the duration of these beneficial effects is unknown. Therefore, the clinical outcomes of the TAXUS I study population were evaluated at 2- and 3-year follow-up. In TAXUS I, 61 patients with single...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 28 21  شماره 

صفحات  -

تاریخ انتشار 2007