Rate of disappearance of labeled carbon dioxide from the lungs of humans during breath holding: a method for studying the dynamics of pulmonary CO2 exchange.

نویسندگان

  • R W Hyde
  • R J Puy
  • W F Raub
  • R E Forster
چکیده

The dynamics of CO(2) exchange in the lungs of man was studied by observing the rate of disappearance of a stable isotope of CO(2) ((13)CO(2)) from the alveolar gas during breath holding. Over 50% of the inspired isotope disappeared within the first 3 sec followed by a moderately rapid logarithmic decline in which one-half of the remaining (13)CO(2) disappeared every 10 sec. The large initial disappearance of (13)CO(2) indicated that alveolar (13)CO(2) equilibrated in less than 3 sec with the CO(2) stored in the pulmonary tissues and capillary blood. The volume of CO(2) in the pulmonary tissues calculated from this initial disappearance was 200 ml or 0.33 ml of CO(2) per milliliter of pulmonary tissue volume. The alveolar to end-capillary gradient for (13)CO(2) was calculated by comparing the simultaneous disappearance rates of (13)CO(2) and acetylene. At rest and during exercise this gradient for (13)CO(2) was either very small or not discernible, and diffusing capacity for CO(2) (D(LCO2)) exceeded 200 ml/(min x mm Hg). After the administration of a carbonic anhydrase inhibitor the rate of disappearance of (13)CO(2) decreased markedly. D(LCO2) fell to 42 ml/(min x mm Hg) and at least 70% of the exchange of (13)CO(2) with the CO(2) stores in the pulmonary tissues and blood was blocked by the inhibitor. These changes were attributed to impairment of exchange of (13)CO(2) with the bicarbonate in the pulmonary tissues and blood. The pH of the pulmonary tissues (V(tis)) was determined by a method based on the premise that the CO(2) space in the pulmonary tissues blocked by the inhibitor represented total bicarbonate content. At an alveolar P(CO2) of 40 mm Hg pH of V(tis) equalled 6.97 +/- 0.09.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary diffusing capacities for oxygen-labeled CO2 and nitric oxide in rabbits.

We determined the pulmonary diffusing capacity (DL) for 18O-labeled CO2 (C18O2) and nitric oxide (NO) to estimate the membrane component of the respective gas conductances. Six anesthetized paralyzed rabbits were ventilated by a computerized ventilatory servo system. Single-breath maneuvers were automatically performed by inflating the lungs with gas mixtures containing 0.9% C18O2 or 0.05% NO i...

متن کامل

Modeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor

comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...

متن کامل

Polyvinylidene Fluoride Hollow Fiber Membrane Contactor Incorporating Surface Modifying Macromolecule for Carbon Dioxide Stripping from Water

Porous surface modified polyvinylidene ï‌‚uoride (PVDF) hollow fiber membranes are fabricated through a dry-wet phased inversion process. Surface modifying macromolecules (SMM) (1 wt. %) are used as additives in the spinning dope. The performance of the surface modified membrane in contactor application for CO2 stripping from water is assessed through the fabricated gas–liquid membrane contacto...

متن کامل

The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test

Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n = 14), 45 ...

متن کامل

The Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)

Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 47 7  شماره 

صفحات  -

تاریخ انتشار 1968