Micro-particle image velocimetry for velocity profile measurements of micro blood flows.

نویسندگان

  • Katie L Pitts
  • Marianne Fenech
چکیده

Micro-particle image velocimetry (μPIV) is used to visualize paired images of micro particles seeded in blood flows. The images are cross-correlated to give an accurate velocity profile. A protocol is presented for μPIV measurements of blood flows in microchannels. At the scale of the microcirculation, blood cannot be considered a homogeneous fluid, as it is a suspension of flexible particles suspended in plasma, a Newtonian fluid. Shear rate, maximum velocity, velocity profile shape, and flow rate can be derived from these measurements. Several key parameters such as focal depth, particle concentration, and system compliance, are presented in order to ensure accurate, useful data along with examples and representative results for various hematocrits and flow conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High Spatial Method to Determine Three-Dimensional Velocity Gradient Tensor using Micro Particle Image Velocimetry

Micro Particle Image Velocimetry (μPIV) is a non-invasive flow field measurement technique, which is becoming the method of choice for the investigation of micro-flows. Measurements of flows which occur within the human body represent one of the most important applications of μPIV. A three-component two-dimensional scanning micro-Particle Image Velocimetry (μPIV) technique is presented in this ...

متن کامل

Measurement of Periodic Flow Using Micro Particle Im- Age Velocimetry with Phase Sampling Technique

ABSTRACT This paper reports a new method for measurement of periodic flows with phase-sampling technique by using conventional micro particle image velocimetry (PIV). Non-integer multiples for the laser pulse frequency and the frequency of the periodic flow are chosen such that each velocimetry data set represents a unique point in phase for the periodic flow. The method we proposed does not re...

متن کامل

Blood Velocity Profile Measurements in Microchannels Using Micro-particle Image Velocimetry

Experimental studies of blood microflows in rectangular biocompatible polymer microchannels measured using micro-particle image velocimetry are reported. The data processing methods, data collection methods, and choice of channel material are demonstrated to impact the velocity profile measurements obtained. Results show that the use of red blood cells as tracer particles creates a large depth ...

متن کامل

Flow velocity profile of micro counter-current flows.

Flow velocity profiles of micro counter-current flow of aqueous and butylacetate phases in a microchannel having a width of 100 microm were measured by micro particle image velocimetry. In order to analyze the hydrodynamic characteristics of the counter-current flow, we derived a simple analytical model for the velocity profile. When flow rates of the aqueous and organic phases were 0.2 and 0.1...

متن کامل

Electro-osmosis-driven micro-channel flows: A comparative study of microscopic particle image velocimetry measurements and numerical simulations

This paper presents global and point-wise comparisons of experimental measurements and numerical simulation results of electro-osmotically driven flows in two elementary micro-channel configurations, a straight channel with a groove and a T-junction channel. The microchannels are made by photolithography using poly-dimethylsiloxane (PDMS), a type of silicon product, which is transparent, and el...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 74  شماره 

صفحات  -

تاریخ انتشار 2013