Intercomparison of seven radioimmunoassay kits and a fluorescence polarization immunoassay kit for digoxin.
نویسندگان
چکیده
Samples from 33 patients being treated with digoxin and three concentrations of control material were analyzed for this drug by use of seven radioimmunoassay (RIA) kits and an automated fluorescence polarization immunoassay (FPIA) system. CVs ranged from 2.4 to 6.4% for the FPIA system and from 4.6 to 7.4% for two RIA methods. In the analysis of between-method variability of RIA kits, CVs ranged from 6.1 to 33.2%. We compared each RIA kit with the other six RIA kits (I), as well as each RIA kit with the FPIA system (II). Correlation coefficients were greater than or equal to 0.96 in all cases. Slopes ranged from 0.82 to 1.20 for comparison I and from 0.86 to 1.01 for comparison II. For the FPIA system, analytical recovery of digoxin ranged from 94 to 104%. For the RIA methods we examined, analytical recoveries ranged from 113 to 135%. Analysis time is shorter and precision is greater for the FPIA system than for the RIA methods.
منابع مشابه
Modified fluorescence polarization immunoassay compared with radial partition immunoassay and a radioimmunoassay for digoxin.
To verify this assumption we evaluated another kit, the “/3hCG MAIA-clone immunoradiometric assay” (Serono), comparing the effects of lipemia on the results obtained with it and with Clinical Assays’ monoclonal antibody kits; we used sera from seven male patients, selected for hipemia. We also examined the effects of free fatty acids at concentrations of 1 g/L in hCG-free serum. Both assays wer...
متن کاملRadioimmunoassay of digoxin: an intercomparison of results with three methods.
The radioimmunoassay of digoxin has been examined by comparing RIA data obtained by a clinical laboratory using the method of Smith et al. [New Engi. J. Med. 281, 1212 (1969)] with data obtained in a laboratory using commercially produced [3H]digoxin and [1251]digoxin kits. Correlations between clinical laboratory data and the results with each kit and correlation between kits are presented. Th...
متن کاملComparison of Common Commercial Immunoassay Kits for Effective Application in Workplace Drug Urinalysis
Workplace drug urinalysis protocols include an initial immunoassay followed by a confirmatory gas chromatography/mass spectrometry (GC/MS) test of immunoassaypositive samples. (Drug categories that are commonly tested include: amphetamines, barbiturates, benzodiazepines, cannabis, cocaine, lysergic acid diethylamide, methadone, methaqualone, opiates, phencyclidine, and propoxyphene. Not all dru...
متن کاملVariability among commercially available digoxin radioimmunoassay kits in cross reactivity to dihydrodigoxin.
We evaluated four commercially available 125I-digoxin radioimmunoassay kits with regard to their ability to cross react with the digoxin metabolite dehydrodigoxin. We prepared dihydrodigoxin serum samples in digoxin-free serum over the concentration range 0.4 to 5.0 microgram/liter and assayed them with each kit according to the manufacturer's instructions. The metabolite was able to displace t...
متن کاملNegligible interference by spironolactone and prednisone in digoxin radioimmunoassay.
Spironolactone and prednisone reportedly cause measurable values for apparent digoxin, even when none is present. Effects of these medications were evaluated with 125I-labeled digoxin kits from five different manufacturers. Values obtained for apparent digoxin were either negligible or not sufficiently great to be clinically significant, regardless of kit methodology or manufacturer.