Dynamic Measurement Uncertainty of Hv Voltage Dividers
نویسندگان
چکیده
− Recently we proposed an approach based on digital filtering for evaluating dynamic non-stationary contributions to the measurement uncertainty. A dynamic simulator instead of a digital filter bank is here utilized for deriving the dynamic measurement uncertainty of mixed capacitive voltage dividers. These are used for lightning impulse measurements, during a calibration measurement of a standard lightning impulse.
منابع مشابه
The Design and Characterization of a Prototype Wideband Voltage Sensor Based on a Resistive Divider
The most important advantage of voltage dividers over traditional voltage transformers is that voltage dividers do not have an iron core with non-linear hysteresis characteristics. The voltage dividers have a linear behavior with respect to over-voltages and a flat frequency response larger frequency range. The weak point of a voltage divider is the influence of external high-voltage (HV) and e...
متن کاملMulti-objective Dynamic Planning of Substations and Primary Feeders Considering Uncertainties and Reliability
This research uses a comprehensive method to solve a combinatorial problem of distribution network expansion planning (DNEP) problem. The proposed multi-objective scheme aims to improve power system's accountability and system performance parameters, simultaneously, in the lowest possible costs. The dynamic programming approach is implemented in order to find the optimal sizing, siting and timi...
متن کاملComparative High Voltage Impulse Measurement
A facility has been developed for the determination of the ratio of pulse high voltage dividers over the range from 10 kV to 300 kV using comparative techniques with Kerr electro-optic voltage measurement systems and reference resistive voltage dividers. Pulse voltage ratios of test dividers can be determined with relative expanded uncertainties of 0.4 % (coverage factor k = 2 and thus a two st...
متن کاملThe Voltage and Time Parameter Measurement Uncertainties of a Large Damped Capacitor Divider due to its Non-ideal Step Response
Limited frequency response of impulse voltage dividers contributes to the measurement errors of the peak voltage and time parameters. This paper investigates the convolution method for the determination of the errors of lightning impulse parameters due to non-ideal step responses. The step response of a damped capacitor divider with a voltage rating of 2.2 MV was measured and analytical lightni...
متن کاملCharacterisation at Low Voltage of Two Reference Lightning Impulse Dividers
An effort is pursued by several European National Measurement Institutes to lower the uncertainties in calibration of UHV measuring systems for lighting impulse. To this end, several reference dividers are investigated as regards their accuracy both for amplitude and for time parameters. At SP RISE Research Institutes of Sweden, a 500 kV resistive reference divider has been in use since 2000. A...