The effects of positive end-expiratory pressure on respiratory system mechanics and hemodynamics in postoperative cardiac surgery patients.

نویسندگان

  • J O Auler
  • M J Carmona
  • C V Barbas
  • P H Saldiva
  • L M Malbouisson
چکیده

We prospectively evaluated the effects of positive end-expiratory pressure (PEEP) on the respiratory mechanical properties and hemodynamics of 10 postoperative adult cardiac patients undergoing mechanical ventilation while still anesthetized and paralyzed. The respiratory mechanics was evaluated by the inflation inspiratory occlusion method and hemodynamics by conventional methods. Each patient was randomized to a different level of PEEP (5, 10 and 15 cmH2O), while zero end-expiratory pressure (ZEEP) was established as control. PEEP of 15-min duration was applied at 20-min intervals. The frequency dependence of resistance and the viscoelastic properties and elastance of the respiratory system were evaluated together with hemodynamic and respiratory indexes. We observed a significant decrease in total airway resistance (13.12 +/- 0.79 cmH2O l-1 s-1 at ZEEP, 11.94 +/- 0.55 cmH2O l-1 s-1 (P<0.0197) at 5 cmH2O of PEEP, 11.42 +/- 0.71 cmH2O l-1 s-1 (P<0.0255) at 10 cmH2O of PEEP, and 10.32 +/- 0.57 cmH2O l-1 s-1 (P<0.0002) at 15 cmH2O of PEEP). The elastance (Ers; cmH2O/l) was not significantly modified by PEEP from zero (23.49 +/- 1.21) to 5 cmH2O (21.89 +/- 0.70). However, a significant decrease (P<0.0003) at 10 cmH2O PEEP (18.86 +/- 1.13), as well as (P<0.0001) at 15 cmH2O (18.41 +/- 0.82) was observed after PEEP application. Volume dependence of viscoelastic properties showed a slight but not significant tendency to increase with PEEP. The significant decreases in cardiac index (l min-1 m-2) due to PEEP increments (3.90 +/- 0.22 at ZEEP, 3.43 +/- 0.17 (P<0. 0260) at 5 cmH2O of PEEP, 3.31 +/- 0.22 (P<0.0260) at 10 cmH2O of PEEP, and 3.10 +/- 0.22 (P<0.0113) at 15 cmH2O of PEEP) were compensated for by an increase in arterial oxygen content owing to shunt fraction reduction (%) from 22.26 +/- 2.28 at ZEEP to 11.66 +/- 1.24 at PEEP of 15 cmH2O (P<0.0007). We conclude that increments in PEEP resulted in a reduction of both airway resistance and respiratory elastance. These results could reflect improvement in respiratory mechanics. However, due to possible hemodynamic instability, PEEP should be carefully applied to postoperative cardiac patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The prophylactic effect of different levels of positive end-expiratory pressure on the incidence rate of atelectasis after cardiac surgery: A Randomized Controlled Trial

&nbsp;&nbsp;&nbsp; Background: The use of positive end-expiratory pressure (PEEP) can have an important role as one of the ways to prevent and treat atelectasis, but it seems that there is still no consensus about its beneficial level. The aim of this study was to determine the effect of different levels of PEEP on the incidence of atelectasis after heart surgery. &nbsp;&nbsp; Methods: This is...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Effects of PEEP on respiratory mechanics after open heart surgery.

Respiratory dysfunction, particularly atelectasis, is common after open heart surgery. Routine use of PEEP (5 to 10 cm H2O) in these patients has been advocated. We studied the effects of different levels of PEEP on respiratory mechanics in ten mechanically ventilated open heart surgery patients in the immediate postoperative period. PEEP was studied in increasing increments and decreasing decr...

متن کامل

The Effect of Low Tidal Volume Ventilation during Cardiopulmonary Bypass on Postoperative Pulmonary Function

BACKGROUND Postoperative pulmonary dysfunction is one of the most frequent complications after cardiac surgery and it is believed to result from the use of cardiopulmonary bypass (CPB). In this study, we investigated the effect of low tidal volume ventilation during CPB on postoperative gas exchange and lung mechanics. METHODS This prospective randomized study included 100 patients undergoing...

متن کامل

Effects of recruitment maneuver and positive end-expiratory pressure on respiratory mechanics and transpulmonary pressure during laparoscopic surgery.

BACKGROUND The authors tested the hypothesis that during laparoscopic surgery, Trendelenburg position and pneumoperitoneum may worsen chest wall elastance, concomitantly decreasing transpulmonary pressure, and that a protective ventilator strategy applied after pneumoperitoneum induction, by increasing transpulmonary pressure, would result in alveolar recruitment and improvement in respiratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2000