Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation

نویسندگان

  • Hilario Pellicer-Chover
  • David Peñarrocha-Oltra
  • Amparo Aloy-Prosper
  • José-Carlos Sanchis-Gonzalez
  • María Peñarrocha-Diago
  • Miguel Peñarrocha-Diago
چکیده

BACKGROUND To compare the technique of high speed drilling with irrigation and low speed drilling without irrigation in order to evaluate the success rate and peri-implant bone loss at 12 months of follow-up. MATERIAL AND METHODS A randomized, controlled, parallel-group clinical trial was carried out in patients requiring dental implants to rehabilitate their unitary edentulism. Patients were recruited from the Oral Surgery Unit of the University of Valencia (Spain) between September 2014 and August 2015. Patients who met the inclusion criteria were randomized to two groups: group A (high-speed drilling with irrigation) and group B (low-speed drilling without irrigation). The success rate and peri-implant bone loss were recorded at 12 months of follow-up. RESULTS Twenty-five patients (9 men and 16 women) with 30 implants were enrolled in the study: 15 implants in group A and 15 implants in group B. The mean bone loss of the implants in group A and group B was 0.83 ± 0.73 mm and 0.62 ± 0.70 mm, respectively (p> 0.05). In the maxilla, the bone loss was 1.04 ± 0.63 mm in group A and 0.71 ± 0.36 mm in group B (p> 0.05), while bone loss in the mandible was 0.59 ± 0.80 mm in group A and 0.69 ± 0.77 mm in group B (p> 0.05). The implant success rate at 12 months was 93.3% in group A and 100% in group B. CONCLUSIONS Within the limitations of the study, the low-speed drilling technique presented peri-implant bone loss outcomes similar to those of the conventional drilling technique at 12 months of follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temperature change in pig rib bone during implant site preparation by low-speed drilling

OBJECTIVES The purpose of this study was to evaluate the temperature change during low-speed drilling using infrared thermography. MATERIAL AND METHODS Pig ribs were used to provide cortical bone of a similar quality to human mandible. Heat production by three implant drill systems (two conventional drilling systems and one low-speed drilling system) was evaluated by measuring the bone temper...

متن کامل

The effect of low-speed drilling without irrigation on heat generation: an experimental study.

OBJECTIVES In this study we evaluated heat generation during the low-speed drilling procedure without irrigation. MATERIALS AND METHODS Ten artificial bone blocks that were similar to human D1 bone were used in this study. The baseline temperature was 37.0℃. We drilled into 5 artificial bone blocks 60 times at the speed of 50 rpm without irrigation. As a control group, we drilled into an addi...

متن کامل

Novel hybrid drilling protocol: evaluation for the implant healing--thermal changes, crestal bone loss, and bone-to-implant contact.

OBJECTIVES To evaluate a new hybrid drilling protocol, by the analysis of thermal changes in vitro, and their effects in the crestal bone loss and bone-to-implant contact in vivo. MATERIALS AND METHODS Temperature changes during simulated osteotomies with a hybrid drilling technique (biologic plus simplified) (test) versus an incremental drilling technique (control) were investigated. One hun...

متن کامل

A Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve

Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...

متن کامل

Hammering K-wires is Superior to Drilling with Irrigation

Cooling during drilling Kirschner wires is not always effective in preventing thermal related damage. In this study, we used a human in vitro model and compared temperature elevation, insertion time, and extraction force between three Kirschner wire insertion methods-drilling with and without irrigation and pneumatic hammering. Forty five Kirschner wires were inserted into 15 fresh human cadave...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2017