CO FROM RADIAL TRACE IN IA BALLOON PUMP/Herzlinger
نویسنده
چکیده
19. Morrison DF: Multivariate Statistical Methods. New York, McGrawHill, 1967, p 125 20. Barach AL: The therapeutic use of oxygen in heart disease. Ann Intern Med 5: 428, 1931 21. Boland EW: Oxygen in high concentrations for relief of pain in coronary thrombosis and severe angina pectoris. JAMA 114: 1512, 1940 22. Sukumalchantra Y, Levy S, Danzig R, Rubins S, Alpern H, Swan HJC: Correcting arterial hypoxemia by oxygen therapy in patients with acute myocardial infarction. Am J Cardiol 24: 838, 1969 23. Angell CS, Lakatta EG, Weisfeldt ML, Shock NW: Relationship of intramyocardial oxygen tension and epicardial ST segment changes following acute coronary artery ligation: Effects of coronary perfusion pressure. Cardiovasc Res 9: 12, 1975 24. Davidson RM, Ramo BW, Wallace AG, Whalen RE, Starmer F: Bloodgas and hemodynamic responses to oxygen in acute myocardial infarction. Circulation 47: 704, 1973 25. Roberts WC: Coronary arteries in fatal acute myocardial infarction. Circulation 45: 215, 1972 26. Ishikawa K, Sarma R, Getzen JH, McNair JD, Cosby RS: Fall in myocardial contractility following 100%0o oxygen breathing in patients with and without coronary artery disease. (abstr) Circulation 48 (suppl IV): IV-180, 173 27. Clark JM, Lambertsen CJ: Pulmonary oxygen toxicity: A review. Pharmacol Reviews 23: 37, 1971 28. Van De Water JM, Kagey KS, Miller JT, Parker DA, O'Connor NE, Shen J-M, MacArthur JD, Zollinger RM, Moore FD: Response of the lung to six to 12 hours of 100 percent oxygen inhalation in normal man. N Engl J Med 283: 621, 1970 29. Paine JR, Lynn D, Keys A: Observations on the effects of the prolonged administration of high oxygen concentration to dogs. J Thorac Surg 11: 151, 1941 30. Clark JM: The toxicity of oxygen. Am Rev Resp Dis 110: 40, 1974
منابع مشابه
Absolute determination of cardiac output in intra-aortic balloon pumped patients using the radial arterial pressure trace.
We describe a new method for the absolute determination of cardiac output in intra-aortic balloon pumped (IABP) patients. The method uses the known pumping volume of the IABP balloon and the radial arterial pressure trace, which is commonly used to monitor IABP patients, to determine the cardiac output. Two pressure excursions denoted by P1-P0 and P2-P0, characterizing IABP balloon deflation, a...
متن کاملA novel technique for intra-aortic balloon positioning in the intensive care unit.
Proper positioning of the intra-aortic balloon catheter is very important as an improperly placed balloon can cause problems. A balloon placed too high can block off the arch vessels, whereas one placed too low can block the renal and splanchnic vessels. We propose a simple and reliable technique to properly position the intra-aortic balloon pump (IABP) catheter without the use of any sophistic...
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملPii: S1010-7940(99)00306-1
Objective: To determine if arterial conduit selection or more ef®cient arterial revascularization techniques in ̄uence in-hospital mortality. Methods: Data from patients undergoing coronary artery bypass surgery at Royal Melbourne Hospital, Australia, between 1 January 1996 and 30 June 1998 (n 1681) was collected prospectively. Logistic regression analysis was performed. Results: Independent p...
متن کاملComparison of the right internal thoracic artery and radial artery as a second arterial conduit in ‘Y’ composite fashion in patients undergoing coronary artery bypass grafting using total arterial revascularization
Introduction: The use of two arterial conduits for CABG is rapidly increasing. The second arterial conduit to LITA is usually RITA or radial artery. We sought to compare outcomes when either RITA or radial artery is exclusively used as a Y composite graft to LITA for total arterial revascularization. Material and methods: We retrospectively analyzed 231 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005