Serology of Legionnaires disease: comparison of indirect fluorescent antibody, immune adherence hemagglutination, and indirect hemagglutination tests.

نویسندگان

  • D A Lennette
  • E T Lennette
  • B B Wentworth
  • M L French
  • G L Lattimer
چکیده

An immune adherence hemagglutination (IAHA) test for the measurement of antibodies to Legionella pneumophila was developed and evaluated for the diagnosis of Legionnaires disease. Its sensitivity was compared to that of the indirect fluorescent antibody (IFA) test and a recently developed indirect hemagglutination (IHA) test. The sensitivity of the three tests appeared to be similar, with the IFA test giving slightly higher titers. Both the IHA and IAHA tests appear useful for the serodiagnosis of Legionnaires disease; the IAHA test has the advantage that it can be used with many other serological antigens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of antibodies to Epstein-Barr virus capsid antigen by immune adherence hemagglutination.

The immune adherence hemagglutination assay was found to be as sensitive and specific as the indirect immunofluorescence technique for titration of antibodies to Epstein-Barr virus capsid antigen. Satisfactory virus capsid antigen-specific and negative control antigens for the immune adherence hemagglutination assay were prepared from cell extracts of the Epstein-Barr virus producer P3HR-1 and ...

متن کامل

Comparison of indirect hemagglutination and indirect immunofluorescence tests with microneutralization tests for detection of type-specific Herpesvirus hominis antibody.

Indirect hemagglutinating and immunofluorescent antibody responses to Herpesvirus hominis types 1 and 2 were compared to neutralizing antibody responses in infected humans from whom H. hominis type 1 or 2 was isolated. The indirect immunofluorescent antibody test was shown to be the most sensitive and specific for primary human infections. The sensitivity and specificity of the indirect hemaggl...

متن کامل

Comparison of indirect fluorescent-antibody amoebic serology with counterimmunoelectrophoresis and indirect hemagglutination amoebic serologies.

Patients ranged from those with no prior diagnosis of or suspected exposure to Entamoeba histolytica to those with proven amoebic liver abscesses (extraintestinal disease). A comparison of serologies from patients with proven and suspected amoebiasis or possible past exposure revealed good correlation between the indirect fluorescent antibody (IFA) procedure and the other methods used, counteri...

متن کامل

Simplification of immune adherence hemagglutination test for detection of rabies antibodies in human serum.

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occurred with low titers. The IAHA test is extremely sim...

متن کامل

Comparison of five methods of cytomegalovirus antibody screening of blood donors.

A group of 120 sera from blood donors was screened by complement fixation and commercially available immunofluorescence, solid-phase fluorescence immunoassay, enzyme-linked immunosorbent assay, and indirect hemagglutination tests. Twenty-four of the sera were positive by three or more of the five tests and judged to be true positives; 89 were negative by three or more of the tests and considere...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 1979