Assessment of left ventricular outflow tract geometry in non-stenotic and stenotic aortic valves by cardiovascular magnetic resonance.

نویسندگان

  • Christof Burgstahler
  • Markus Kunze
  • Christine Löffler
  • Meinrad P Gawaz
  • Vinzenz Hombach
  • Nico Merkle
چکیده

PURPOSE To assess the geometry and area of the left ventricular outflow tract (LVOT) in non-stenotic and stenotic aortic valves and to determine the aortic valve area (AVA) in non-stenotic valves by magnetic resonance imaging (MRI) using a modified continuity equation. METHODS Twenty patients (10 male, mean age 54.8 +/- 15 years) without known aortic valve disease and 10 patients (7 male, mean age 65.1 +/- 14 years) with moderate to severe aortic stenosis were included in this study. MRI was performed using a 1.5 T scanner (Philips Intera CV). AVA was assessed by planimetry on high quality SSFP cine sequences and used as reference standard. LVOT area was defined by calculating a circular area using the LVOT diameter from the 3 chamber view (3CV) and by planimetry. Peak flow velocity was assessed in the LVOT and the proximal aorta. AVA was calculated by a modified Gorlin equation, the continuity equation and a modified continuity equation using the planimetric LVOT area. RESULTS Planimetric AVA ranged from 2.9 to 6.4 cm2 in patients with non-stenotic and from 0.3 to 1.3 cm2 with stenotic valves, LVOT area from 3.4 to 6.1 cm2 and from 2.6 to 6.5 cm2, respectively. The LVOT area based on the LVOT diameter derived from the 3CV was significantly underestimated in comparison to planimetry in non-stenotic and stenotic aortic valves (3.3 +/- 0.7 vs. 4.7 +/- 1.0 cm2, p < 0.0001; mean difference 1.1 +/- 0.12 cm2, CI 0.86-1.36 and 3.7 +/- 1.2 vs. 4.7 +/- 1.5 cm2, p < 0.05; mean difference 1.0 +/- 1.0 cm2, CI 0.24-1.71). The Gorlin formula showed a poor agreement with planimetry, whereas continuity equation and the modified continuity equation revealed a very good agreement. Planimetry of the LVOT displayed an elliptic shape of the LVOT in all patients with the minimum diameter perpendicular to the 3CV, which was the reason for the above mentioned underestimation. CONCLUSION The LVOT area calculated from the 3CV-LVOT diameter underestimates the LVOT area compared to planimetry due to an elliptic shape of the LVOT in patients with non-stenotic as well as with stenotic aortic valves. The modified Gorlin equation proved to be less useful to assess AVA in non-stenotic valves, whereas the continuity equation and a modified continuity equation displayed a very good agreement with planimetric area measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnosis of a non-stenotic bicuspid aortic valve.

Follow-up of a group of subjects in whom an aortic ejection sound was the only abnormal finding revealed a bicuspid aortic valve at necropsy or operation in 6 cases. High speed echophonocardiographic studies in 15 subjects with aortic stenosis and known to have bicuspid valves, showed the ejection sound to be exactly synchronous with final halting of the opening aortic valve cusps. Echocardiogr...

متن کامل

Heart valve disease: investigation by cardiovascular magnetic resonance

Cardiovascular magnetic resonance (CMR) has become a valuable investigative tool in many areas of cardiac medicine. Its value in heart valve disease is less well appreciated however, particularly as echocardiography is a powerful and widely available technique in valve disease. This review highlights the added value that CMR can bring in valve disease, complementing echocardiography in many are...

متن کامل

Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis: comparison with echocardiography.

BACKGROUND Valvular pathology can be analyzed quickly and accurately through the use of Doppler ultrasound. For aortic stenosis, the continuity equation approach with Doppler velocity-time integral (VTI) data is by far the most commonly used clinical method of quantification. In view of the emerging popularity of cardiac magnetic resonance (CMR) as a routine clinical imaging tool, the purposes ...

متن کامل

A simplified continuity equation approach to the quantification of stenotic bicuspid aortic valves using velocity-encoded cardiovascular magnetic resonance.

OBJECTIVE We aimed to compare velocity-encoded cine cardiac magnetic resonance (CMR) with an established echocardiographic method for noninvasive measurement of aortic valve area (AVA) using the continuity equation. METHODS AND RESULTS Twenty consecutive young adults with stenotic bicuspid aortic valves were examined with CMR and transthoracic echocardiography (TTE). CMR AVA was calculated by...

متن کامل

Stenotic mitral valve prosthesis with left atrial thrombus.

We report the CMR findings of a patient with stenotic biological mitral valve prosthesis that was complicated by thrombus formation in the left atrium. The case illustrates the ability of CMR to assess biological prosthetic valves and to provide a comprehensive diagnostic approach in this clinical scenario.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 2006