Use of L+H* for immediate contrast resolution

نویسندگان

  • Kiwako Ito
  • Shari R. Speer
چکیده

Previous eye tracking studies [1] demonstrated that a prominent L+H* accent in English instructions evoked a contrastive relationship between discourse referents, immediately guiding listeners’ eye movements to contrastive candidates in the visual scene. However, the visual layout in the previous study conflated looks to contrastive candidates with those to previously fixated object groups, thus calling into question the cause of the very early fixations to contrastive targets. In order to eliminate the possibility that L+H* evokes contrast only when the visual layout allows easy detection of the target, the current experiment used layouts where contrastive candidates had separate visual domains. The results confirm the immediate effect of L+H*, demonstrating a faster increase in fixations to contrastive targets than with H*. In addition, results show an intonational ‘garden-path effect’ due to the immediate integration of L+H* as contrast marking accent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

A new approach to contrast enhancement in MAGICA gel dosimeter image with MRI technique

parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007