Integrating Radon Progeny Monitor

نویسنده

  • Y. Ishimori
چکیده

INTRODUCTION The Japan Nuclear Cycle Development Institute (JNC) carried out research and development projects related to uranium exploration in Japan from 1967 to 1987. Several mining facilities have been retained after the end of projects. Hence, the study on the behavior and the environmental impact of radon and its progeny from the mining facilities is being continued at the Ningyo-toge Environmental Engineering Center of the JNC (JNC Ningyo-toge). The limitations against radon are determined with equilibrium equivalent radon concentration (EECRn) in current Japanese laws, including the Japanese Mine Safety Law. The Law requires a lower exposure dose than 1mSv/year out of the site, in excess of the natural background level. 1mSv/year is equivalent to 9 Bq/m of EECRn. It is therefore necessary to determine the long-term average concentration of radon progeny. Nevertheless, the environmental impact of radon is generally estimated from radon concentration by integrating radon monitors. This means that the radon progeny concentration monitors, which are suitable for long-term average concentration of radon progeny at outdoor fields where it is impossible to use an AC power source, have not appeared. Actually, long-term environmental surveillances of radon concentration have been carried out more frequently than that of radon progeny concentration. Radon progeny monitors are categorized into active monitors and passive monitors. In general, the response of the active monitor is more stable than the passive monitor. The equilibrium factor (F value) by grab sampling method on and around the mining sites is shown in Figure 1. The variation of the F values is vary widely. Thus, active monitors are suitable for environmental monitoring. Several different techniques using the active method, including integrating monitors, have been used to determine radon progeny concentration. Since some of them require precision systems with AC power sources, they are big and expensive. Although others are simple and use batteries, almost all of them are developed for short-term monitoring; for example, personal dosimetry or area monitoring while working. An integrating radon progeny monitor developed by the JNC Ningyo-toge collects radon progeny on a filter using a pump with a battery and detects alpha particles with a CR-39 detector. However, it differs from others in that it uses interval operation for sampling and it has a function to estimate the effect of components attached by diffusion during interval. This monitor makes possible the long-term measurements of radon progeny concentration for over a month without an AC power source. In this paper, the character of the monitor and the results of experimental measurement at outdoor fields are reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Portable Radon Progeny Monitor for Individual Concentration

INTRODUCTION The Rn(radon) family is the most significant source of exposure to natural radiation, causing about one-half of the public effective dose. A number of international organizations, including UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) and ICRP (International Commission on Radiological Protection) have officially reported this fact since the 1980’...

متن کامل

Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Seasonal variation of radon, thoron and their progeny levels in dwellings of Haryana and Western Uttar Pradesh

Background: Radon and thoron are invisible, odorless, heavy and radioactive gases which are ubiquitously present in dwellings and in the environment. In the present work, seasonal variation of indoor radon, thoron and their progeny concentrations has been studied in the dwellings of industrially polluted cities in District Faridabad, Haryana and District Mathura in Uttar Pradesh. Materials and ...

متن کامل

Method to Measure Indoor Radon Concentration in an Open Volume with Geiger-Mueller Counters: Analysis from First Principles

A simple method employing a pair of pancake-style Geiger-Mueller (GM) counters for quantitative measurement of radon activity concentration (activity per unit volume) is described and demonstrated. The use of two GM counters, together with the basic theory derived in this paper, permit the detection of alpha particles from decay of 222 Rn and progeny ( 218 Po , 214 Po ) and the conversion of th...

متن کامل

Variation of radon progeny concentration over a continental location

Background: The variation of the radon progeny concentration in outdoor environment and meteorological parameters at fine resolution were studied for one year at a continental location, National Atmospheric Research Laboratory, Gadanki, India.  Materials and Methods: The concentrations were measured using Alpha Progeny Meter by collecting air samples at a height of 1 m above the Earth&rsqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000