Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair

نویسندگان

  • Qing-Song Zhang
  • Sen Liu
  • Qiuyang Zhang
  • Yun Xue
  • Dongxia Ge
  • Michael J. O'Brien
  • Felix H. Savoie
  • Zongbing You
چکیده

Objectives. The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems. Methods. 20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems. The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures. The areas of tendon damage were measured. Results. The areas of tendon damage (mean ± standard deviation, n = 7) were 29.1 ± 4.3 mm(2) for the Healix Peek anchor, 20.4 ± 2.3 mm(2) for the Fastin RC anchor, 23.4 ± 1.2 mm(2) for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm(2) for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm(2) for the Healix Transtend anchor inserted through the Percannula system (P < 0.001 or P < 0.001, compared to other anchors). Conclusions. In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues. The Healix Transtend implant system caused the least damage to the tendon tissues. Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transtendon rotator-cuff repair of partial-thickness articular surface tears can lead to medial rotator-cuff failure

PURPOSE The purpose of this study was to evaluate clinical and anatomic outcomes of patients following transtendon rotator-cuff repair of partial articular supraspinatus tendon avulsion (PASTA) lesions. PATIENTS AND METHODS Patients in the senior author's practice who had isolated PASTA lesions treated by transtendon rotator-cuff repair were included (n=8) and retrospectively reviewed. All pa...

متن کامل

Comparison of the Fixation Strength of PEEK Knotless Suture Anchors for Rotator Cuff Repair

INTRODUCTION Rotator cuff injuries are common, with approximately 400,000 cuff repairs performed each year in the United States alone. Surgical repair of torn cuff tendons involves reattachment of the torn end of the tendon to the original footprint on the proximal humerus, typically using suture anchors. In recent years, suture anchors have evolved into knotless systems, which are designed to ...

متن کامل

Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model.

BACKGROUND To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomecha...

متن کامل

Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques.

BACKGROUND Although many studies involving rotator cuff repair fixation have focused on ultimate fixation strength and ability to restore the tendon's native footprint, no studies have characterized the stability of the repair with regard to motion between the tendon and repair site footprint. HYPOTHESIS Suture anchor fixation for rotator cuff repair has greater interface motion between tendo...

متن کامل

Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair

Frontal plane humeral elevation effects on the pullout strength of suture anchors used in rotator cuff repair The rotator cuff offers the stabilizing forces necessary for fine arm movement. The most common injury to the rotator cuff is the partial or full thickness tear of the supraspinatus tendon, which attaches the humerus to the scapula on the superior side, due to an acute or chronic injury...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012