High Resolution Spatial and Timing Observations of Millisecond Pulsar Psr J0218+4232 with Chandra
نویسندگان
چکیده
We report on high-resolution spatial and timing results for binary millisecond pulsar PSR J0218+4232 obtained with the Chandra HRC-I and HRC-S in imaging mode. The sub-arcsecond resolution image of the HRC-I (0.08-10 keV) showed that the X-ray emission from PSR J0218+4232 is consistent with that of a point source excluding the presence of a compact nebula with a size of about 14 for which we had indications in ROSAT HRI data. The presence of a DC component is confirmed. This X-ray DC component has a softer spectrum than the pulsed emission and can be explained by emission from a heated polar cap. With our HRC-S observation we obtained a 0.08-10 keV pulse profile with high statistics showing the well-known double peaked morphology in more detail than before: The two pulses have broad wings and pulsed emission appears only to be absent in a narrow phase window of width ∼< 0.1. The absolute timing accuracy of ∼ 200μs makes it possible to compare for the first time in absolute phase the X-ray pulse profile with the highly structured radio profile and the high-energy γ-ray profile (0.1-1 GeV). The two X-ray pulses are aligned within absolute timing uncertainties with two of the three radio pulses. Furthermore, the two γ-ray pulses are aligned with the two non-thermal X-ray pulses, corresponding to a probability for a random occurrence of 4.9σ, strengthening the credibility of the earlier reported first detection of pulsed high-energy γ-ray emission from a (this) millisecond pulsar. Subject headings: pulsars: individual (PSR J0218+4232 ), X-rays: stars
منابع مشابه
Chandra and Rxte Studies of the X-ray/γ-ray Millisecond Pulsar Psr J0218+4232
We report on high-resolution spatial and timing observations of the millisecond pulsar PSR J0218+4232 performed with the Chandra X-ray Observatory (CXO) and the Rossi X-ray Timing Explorer (RXTE). With these observations we were able to study a) the possible spatial extent at X-ray energies of the DC source coincident with PSR J0218+4232 in detail (CXO), b) the relative phasing between the X-ra...
متن کاملXMM - Newton spectral and timing observations of the millisecond pulsar PSR J 0218 + 4232
We present XMM-Newton MOS imaging and PN timing data of the millisecond pulsar PSR J0218+4232. We confirm the previously detected pulsations of PSR J0218+4232 and we show that the folded lightcurve is dependent on energy. We present the broad band (0.2-10.0 keV) spectrum of this millisecond pulsar, as well as the spectra of: the pulsed emission, the individual pulses, the interpulse and the non...
متن کاملar X iv : a st ro - p h / 98 12 40 8 v 1 2 2 D ec 1 99 8 HIGH - ENERGY OBSERVATIONS OF THE BINARY MILLISECOND PULSAR PSR J 0218 + 4232
We report the detection of pulsed X-ray emission (4.9σ) from the binary millisecond pulsar PSR J0218+4232 in a 100 ks ROSAT HRI observation. The pulse profile shows a sharp main pulse and an indication for a second weaker pulse at ∼ 0.47 phase separation. The pulsed fraction is 37±13%. PSR J0218+4232 was several times in the field of view of the high-energy γ-ray telescope EGRET and a source po...
متن کاملLikely Detection of Pulsed High-energy Γ-rays from Millisecond Pulsar Psr J0218+4232
We report on the likely detection of pulsed high-energy γ-rays from the binary millisecond pulsar PSR J0218+4232 in 100-1000 MeV data from CGRO EGRET. Imaging analysis demonstrates that the highly significant γ-ray source 2EG J0220+4228 (∼ 10σ) is for energies > 100 MeV positionally consistent with both PSR J0218+4232 and the BL Lac 3C66A. However, above 1 GeV 3C66A is the evident counterpart ,...
متن کاملDetection of pulsed X-ray emission from the binary millisecond pulsar PSR J0218+4232
We report the detection of pulsed X-ray emission from the binary millisecond pulsar PSR J0218+4232 in a 100 ks ROSAT HRI observation. The lightcurve deviates from a flat distribution at a ∼ 4.8σ level, showing a sharp main pulse with a duty cycle of ∼ 0.15 (350μs), compatible with smearing due to the scatter in the ROSAT clock calibration. The intrinsic width can be smaller than 100μs. There is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002