Diffusion tensor echo planar imaging using surface coil transceiver with a semiadiabatic RF pulse sequence at 14.1T.

نویسندگان

  • Yohan van de Looij
  • Nicolas Kunz
  • Petra Hüppi
  • Rolf Gruetter
  • Stéphane Sizonenko
چکیده

Diffusion magnetic resonance studies of the brain are typically performed using volume coils. Although in human brain this leads to a near optimal filling factor, studies of rodent brain must contend with the fact that only a fraction of the head volume can be ascribed to the brain. The use of surface coil as transceiver increases Signal-to-Noise Ratio (SNR), reduces radiofrequency power requirements and opens the possibility of parallel transmit schemes, likely to allow efficient acquisition schemes, of critical importance for reducing the long scan times implicated in diffusion tensor imaging. This study demonstrates the implementation of a semiadiabatic echo planar imaging sequence (echo time=40 ms, four interleaves) at 14.1T using a quadrature surface coil as transceiver. It resulted in artifact free images with excellent SNR throughout the brain. Diffusion tensor derived parameters obtained within the rat brain were in excellent agreement with reported values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of in-vivo Diffusion Tensor Echo Planar Imaging and Fiber Tracking at 14.1T

Introduction: Diffusion tensor imaging (DTI) has shown remarkable results over the last decade mainly for tumor detection and tracking brain recovery processes by assessing tissue microstructures information. Indeed, proton magnetic resonance spectroscopy has also shown interest in studying brain development [1] by looking at metabolic changes. Therefore, the combination of DTI with MRS gives a...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: application to high-resolution diffusion tensor imaging.

A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the...

متن کامل

The b matrix in diffusion tensor echo-planar imaging.

In diffusion tensor imaging (DTI) an effective diffusion tensor in each voxel is measured by using a set of diffusion-weighted images (DWIs) in which diffusion gradients are applied in a multiplicity of oblique directions. However, to estimate the diffusion tensor accurately, one must account for the effects of all imaging and diffusion gradient pulses on each signal echo, which are embodied in...

متن کامل

Diffusion tensor imaging in carpal tunnel syndrome.

PURPOSE We aimed to investigate the efficacy of diffusion tensor imaging in the diagnosis of carpal tunnel syndrome and to obtain a quantitative parameter that may contribute to the diagnosis. MATERIALS AND METHODS The median nerves in 57 wrists of 38 patients diagnosed as carpal tunnel syndrome and 30 wrists of 24 normal subjects were prospectively evaluated with a 3T Philips scanner, using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 2011