Optimized and Validated RP-UPLC Method for the Determination of Losartan Potassium and Chlorthalidone in Pharmaceutical Formulations.

نویسندگان

  • Tadiboyina Sirisha
  • Bannimath Gurupadayya
  • Sridhar Siddiraju
چکیده

PURPOSE A validated ultra performance liquid chromatography (UPLC) method has been developed and validated for the simultaneous determination of losartan potassium and chlorthalidone in pharmaceutical preparations. METHODS Waters-Acquity UPLC system equipped with Auto Sampler, PDA detector and operated with Empower-2 software was used for the present study. Detection was done at wavelength of 230 nm, HSS C18, 100 mm x 2.1x 1.8 μm column with a reverse phase elution and mobile phase composed of A and B mixed in the ratio 56:44 v/v (Where mobile phase A consists of potassium dihydrogen phosphate buffer of pH 3.0 and Mobile phase B consists of acetonitrile and methanol mixed in the ratio of 90:10 v/v) used at a flow rate of 0.4ml per minute. RESULTS The retention times for losartan potassium and chlorthalidone were observed at 0.72 and 1.89 minutes. The developed method was validated as per ICH guidelines. Linearity ranges were found to be 12.5-125 μg/ml and 3.125-31.25 μg/ml for losartan potassium and chlorthalidone, respectively. CONCLUSION This method is fast, accurate, precise and sensitive hence it can be employed for routine quality control of tablets containing both drugs in industries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations

Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...

متن کامل

Quantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations

Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...

متن کامل

A Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design

this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...

متن کامل

A Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design

this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Advanced pharmaceutical bulletin

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2015