Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.
نویسندگان
چکیده
To determine intrinsic mechanical properties (elastic and failure) of trabecular calcaneus bone, chosen as a good predictor of hip fracture, we looked for the influence of image's size on a numerical simulation. One cubic sample of cancellous bone (9 x 9 x 9 mm(3)) was removed from the body of the calcaneus (6 females, 6 males, 79+/-9 yr). These samples were tested under compressive loading. Before compressive testing, these samples were imaged at 10.13 microm resolution using a 3D microcomputed tomography (muCT) (ESRF, France). The muCT images were converted to finite-element models. Depending on the bone density values (BV/TV), we compared two different finite element models: a linear hexahedral and a linear beam finite element models. Apparent experimental Young's modulus (E(app)(exp)) and maximum apparent experimental compressive stress (sigma(max)(exp)) were significantly correlated with bone density obtained by Archimedes's test (E(app)(exp)=236+/-231 MPa [19-742 MPa], sigma(max)(exp)=2.61+/-1.97 MPa [0.28-5.81 MPa], r>0.80, p<0.001). Under threshold at 40 microm, the size of the numerical samples (5.18(3) and 6.68(3)mm(3)) seems to be an important parameter on the accuracy of the results. The numerical trabecular Young's modulus was widely higher (E(trabecular)(num)=34,182+/-22,830 MPa [9700-87,211 MPa]) for the larger numerical samples and high BV/TV than those found classically by other techniques (4700-15,000 MPa). For rod-like bone samples (BV/TV<12%, n=7), Young's modulus, using linear beam element (E(trabecular)(num-skeleton): 10,305+/-5500 MPa), were closer to the Young's modulus found by other techniques. Those results show the limitation of hexahedral finite elements at 40 microm, mostly used, for thin trabecular structures.
منابع مشابه
Studying the Mechanical and Thermal Properties of Polymer Nanocomposites Reinforced with Montmorillonite Nanoparticles Using Micromechanics Method
In this study, the mechanical and thermal behavior of the nano-reinforced polymer composite reinforced by Montmorillonite (MMT) nanoparticles is investigated. Due to low cost of computations, the 3D representative volume elements (RVE) method is utilized using ABAQUS finite element commercial software. Low density poly ethylene (LDPE) and MMT are used as matrix and nanoparticle material, respec...
متن کاملA study on behavior of block pavement using 3D finite element method
Three dimensioned finite element analysis were conducted on concrete block paving. In order to verify the calculated results, an experimental case study was analyzed. Good agreement was observed between the measured and the calculated results. Based on the finite element analysis results and available failure models, comprehensive design charts were developed for port and industrial pavement wh...
متن کاملThe ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone.
Bone mineral density (BMD) and bone microarchitecture are important determinants for the mechanical properties of cancellous bone. Although BMD alone is a good predictor of average mechanical properties of cancellous bone, there remains unexplained variation in mechanical properties that might be due to missing information regarding bone microarchitecture. Recent developments in three-dimension...
متن کاملInvestigating the Effect of Joint Geometry of the Gas Tungsten Arc Welding Process on the Residual Stress and Distortion using the Finite Element Method
Although a few models have been proposed for 3D simulation of different welding processes, 2D models are still more effective in design goals, thus more popular due to the short-time analysis. In this research, replacing "time" by the "third dimension of place", the gas tungsten arc welding process was simulated by the finite element method in two dimensions and in a short time with acceptable ...
متن کاملAccurate and fast bone strength predictions of patient- specific plate-rod models based on μCT and HRpQCT images
Aims High resolution computed tomography (CT) image based finite element (FE) models have been widely applied to assess the mechanical properties of human trabecular bone. However, the prohibitive computational cost of voxel-based FE models limits its clinical applications, especially in whole bone strength prediction by nonlinear FE analysis. There is a strong need for an alternative modeling ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 40 10 شماره
صفحات -
تاریخ انتشار 2007