GC-FID determination and pharmacokinetic studies of oleanolic acid in human serum.
نویسندگان
چکیده
Analytical interest of OA determination in human serum has increased owing to the increasing interest in pharmaceutical research by pharmaceutical properties. A simple, specific, precise and accurate GC method with flame ionization detector (FID) developed and validated for the determination of oleanolic acid (OA) in human serum (HS). To an aliquot of HS, internal standard was added and a combination of liquid-liquid extraction with a mixture of diethyl ether-isopropyl alcohol, filtration and consecutive GC resulted in separation and quantification of OA. The organic phase was analyzed using a GC system equipped with a 30 × 0.25 mm i.d. Rtx-65TG capillary column and FID detection. Total chromatographic time was 10 min and no interfering peaks from endogenous components in blank serum were observed. The OA/internal standard peak area ratio was linearly fitted to the OA concentration (r = 0.992) over the range 10-1500 ng/mL. The mean serum extraction recovery of OA was 96.7 ± 1.0% and the lower limit of quantification based on 5 mL of serum was 10.7 ng/mL. The intra-day coefficient of variation ranged from 1.3 to 3.6% and inter-day varied from 1.4 to 4.5%. The developed method was used to study the pharmacokinetics of OA after oral administration in humans. The assay was simple, sensitive, precise and accurate for the use in the study of the mechanisms of absorption and distribution of OA in humans.
منابع مشابه
Development and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia
Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...
متن کاملInvestigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations
The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not o...
متن کاملInvestigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations
The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not o...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملAn Improved GC Method for Rapid Analysis of Valproic Acid in Human Plasma Without Derivatization
A simple, reproducible and rapid gas chromatographic method for precise determination of valproic acid (VPA) in human plasma has been developed. Total time for sample preparation and GC analysis is less than 45 min. After plasma protein precipitation, VPA was extracted into chloroform with suitable recovery. By using Stabilwax®<span styl...