Postacquisition suppression of large-vessel BOLD signals in high-resolution fMRI.

نویسنده

  • Ravi S Menon
چکیده

Large-vessel BOLD contamination is a serious impediment to localization of neural activity in high-resolution fMRI studies. A new method is presented which estimates and removes the fraction of BOLD signal that arises from oriented vessels, such as cerebral and pial veins in a voxel, by measuring their influence on the phase angle of the complex valued fMRI time series. A maximum likelihood estimator based on a linear least-squares fit of the BOLD signal phase to the BOLD signal magnitude in a voxel is shown to efficiently suppress the BOLD effect from these larger veins, whose activation is not well colocalized with the neural response. In high-resolution in vivo fMRI data at 4 T, it is estimated that the method is sensitive to the phase changes in the cerebral, larger intracortical, and pial veins. The technique requires no special pulse sequence modifications or acquisition strategies, and is computationally fast and intrinsically robust.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Modeling both the magnitude and phase of complex-valued fMRI data.

In MRI and fMRI, images or voxel measurement are complex valued or bivariate at each time point. Recently, (Rowe, D.B., Logan, B.R., 2004. A complex way to compute fMRI activation. NeuroImage 23 (3), 1078-1092) introduced an fMRI magnitude activation model that utilized both the real and imaginary data in each voxel. This model, following traditional beliefs, specified that the phase time cours...

متن کامل

Characterizing phase-only fMRI data with an angular regression model.

FMRI voxel time series are complex-valued with real and imaginary parts that are usually converted to magnitude-phase polar coordinates. Magnitude-only data models that discard the phase portion of the data have dominated fMRI analysis. However, when such analyses are performed, the data that is discarded may contain valuable biologic information that is not in the magnitude data. This biologic...

متن کامل

Reducing the unwanted draining vein BOLD contribution in fMRI with statistical post-processing methods

Recent BOLD fMRI data analysis methods show promise in reducing contributions from draining veins. The phase regressor method developed by [Menon, R.S., 2002. Post-acquisition suppression of large-vessel BOLD signals in high-resolution fMRI. Magn. Reson. Med., 47, 1-9] creates phase and magnitude images, regresses magnitude as a function of phase, and subtracts phase-estimated magnitudes from t...

متن کامل

Combined gradient- and spin-echo EPI acquisition technique for high-resolution fMRI

INTRODUCTION – Gradient-echo (GRE) based fMRI pulse sequences are most sensitive to larger vessels, including veins. The regions-of-interest for neuronal activity, however, are mainly within capillaries. Effective localization of brain activity would require that the BOLD signal is confined to the microvasculature. However, in GRE-based sequences BOLD signal changes tend to be located distant t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2002