The Influence of Intensity Standardization on Medical Image Registration

نویسندگان

  • Ulas Bagci
  • Jayaram K. Udupa
  • Li Bai
چکیده

Acquisition-to-acquisition signal intensity variations (non-standardness) are inherent in MR images. Standardization is a post processing method for correcting intersubject intensity variations through transforming all images from the given image gray scale into a standard gray scale wherein similar intensities achieve similar tissue meanings. The lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterizability, image display, and analysis, including image segmentation. This phenomenon has been documented well; however, effects of standardization on medical image registration have not been studied yet. In this paper, we investigate the influence of intensity standardization in registration tasks with systematic and analytic evaluations involving clinical MR images. We conducted nearly 20,000 clinical MR image registration experiments and evaluated the quality of registrations both quantitatively and qualitatively. The evaluations show that intensity variations between images degrades the accuracy of registration performance. The results imply that the accuracy of image registration not only depends on spatial and geometric similarity but also on the similarity of the intensity values for the same tissues in different images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of intensity standardization in medical image registration

0167-8655/$ see front matter Crown Copyright 2 doi:10.1016/j.patrec.2009.09.010 * Corresponding author. E-mail addresses: [email protected] (U. Bağcı Udupa), [email protected] (L. Bai). URL: http://www.ulasbagci.net (U. Bağcı). Acquisition-to-acquisition signal intensity variations (non-standardness) are inherent in MR images. Standardization is a post processing method for correcting inter-su...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Intensity non-standardness affects computer recognition of anatomical structures

Since MR image intensities do not possess a tissue specific numeric meaning, even in images acquired for the same subject, on the same scanner, for the same body region, by using the same pulse sequence, it is important to transform the image scale into a standard intensity scale so that, for the same body region, intensities are similar. The lack of a standard image intensity scale in MRI lead...

متن کامل

A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information

Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...

متن کامل

Surface reconstruction of detect contours for medical image registration purpose

Although, most of the abnormal structures of human brain do not alter the shape of outer envelope of brain (surface), some abnormalities can deform the surface extensively. However, this may be a major problem in a surface-based registration technique, since two nearly identical surfaces are required for surface fitting process. A type of verification known as the circularity check for th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • CoRR

دوره abs/1002.1285  شماره 

صفحات  -

تاریخ انتشار 2010