New quantitative model of aortic valve in PreTAVI patients.

نویسندگان

  • Ana García-Martín
  • Covadonga Fernández-Golfín
  • José Luis Zamorano-Gómez
چکیده

Application of percutaneous techniques is a major advance in the field of structural cardiology that has been extended to a large number of diseases that were previously treated surgically or had no available treatment. Advancing these techniques requires a precise knowledge of cardiovascular anatomy, and the various imaging methods have become an indispensable tool in their development. To this end, a new specialized software has emerged, which can automatically configure—with minor manual changes—a geometric model of the aortic root from images obtained by 3-dimensional transesophageal echocardiography and perform quantitative analysis of these structures (Auto Valve Analysis, Siemens, California, United States). We present a case in which this new program was used for the preprocedure evaluation of transcatheter aortic valve implantation (TAVI). Aortic annulus measurement was 22 25 mm by 3-dimensional transesophageal echocardiography (Figure 1), 20 24 mm by computed tomography, (Figure 2), and 25 mm (Figure 3) with the new software. Ultimately, a 26-mm Edwards-SAPIEN XT aortic valve was successfully implanted. The ability to predict the outcome of TAVI with image-based geometric models is one of the possibilities offered by this new software. Automatic handling of the images, with acquisition of a larger number of measurements than those evaluable manually, as well as the shorter time period needed and greater reproducibility, are some of the advantages of this software over the techniques available to date, such as echocardiography and computed tomography. 3D Quantification

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

Doppler echocardiographic findings in tissue engineered aortic valve in a sheep model

Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 2014