Prevalence of adverse reactions to metal debris following metal-on-metal THA.

نویسندگان

  • Masahiro Hasegawa
  • Kakunoshin Yoshida
  • Hiroki Wakabayashi
  • Akihiro Sudo
چکیده

The purpose of this study was to determine the prevalence of adverse reactions to metal debris (ARMD) following large-diameter metal-on-metal total hip arthroplasty. The authors examined the potential for using magnetic resonance imaging to screen for pseudotumors in 108 hips 2 years postoperatively. Serum cobalt and chromium concentrations were measured in 80 hips that underwent unilateral total hip arthroplasty. The authors considered pseudotumors and aseptic lymphocyte-dominated vasculitis-associated lesions to be ARMD and compared metal ion levels between hips with ARMD (ARMD group) with hips with no ARMD (non-ARMD group). Magnetic resonance imaging revealed pseudotumors in 9 patients (10 hips, 9%). Five of these 10 hips were symptomatic and underwent revision surgery. Two other patients underwent revision surgery due to symptomatic cup loosening with aseptic lymphocyte-dominated vasculitis-associated lesions. Ten patients (12 hips) had ARMD. Serum cobalt and chromium concentrations were significantly higher in hips with ARMD than hips without ARMD. Other factors, including age, body mass index, sex, clinical score, acetabular cup inclination angle, and femoral head diameter, were not significantly different between the groups. Elevated metal ion levels suggest that ARMD is associated with increased metal wear. Magnetic resonance imaging provides sensitive screening for pseudotumors following metal-on-metal total hip arthroplasty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty

BACKGROUND The purpose of the present study was to determine whether T cell-mediated type IV hypersensitivity reactions could be a major cause of adverse reaction to metal debris (ARMD) after metal-on-metal total hip arthroplasty (THA). METHODS Thirteen patients (1 man and 12 women; mean age 68 years, age range 60 to 83 years) with ARMD underwent revision surgery following metal-on-metal THA ...

متن کامل

ANAlysis oF 185 RevisioNs FRoM tHe NAtioNAl JoiNt RegistRy FoR eNglAND AND WAles

vol. 6, No. 7, July 2017 405 Article focus „ Few studies have assessed the outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD), despite this clinical problem being increasingly reported worldwide. outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip art...

متن کامل

Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management

Recent alarming joint registry data highlighting increased revision rates has prompted further research into the area of metal-on-metal hip replacements and resurfacings. This review article examines the latest literature on the topic of adverse reactions to metal debris and summarises the most up-to-date guidelines on patient management. Adverse reactions to metal debris can cause significant ...

متن کامل

Current Insights Regarding Metal-On-Metal Bearings for Hip Arthroplasty "2279

Modern small diameter metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have been developed in the nineteen-eighties to address the problem of polyethylene wear related osteolysis. Subsequently large diameter MoM hip resurfacings (HRA) were designed for young and active patients to preserve bone and avoid dislocation. Large diameter MoM THA were originally meant as an easy femoral ...

متن کامل

Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty

BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 36 5  شماره 

صفحات  -