Determinants of PCR performance (Xpert MTB/RIF), including bacterial load and inhibition, for TB diagnosis using specimens from different body compartments
نویسندگان
چکیده
The determinants of Xpert MTB/RIF sensitivity, a widely used PCR test for the diagnosis of tuberculosis (TB) are poorly understood. We compared culture time-to-positivity (TTP; a surrogate of bacterial load), MTB/RIF TB-specific and internal positive control (IPC)-specific C(T) values, and clinical characteristics in patients with suspected TB who provided expectorated (n = 438) or induced sputum (n = 128), tracheal aspirates (n = 71), bronchoalveolar lavage fluid (n = 152), pleural fluid (n = 76), cerebral spinal fluid (CSF; n = 152), pericardial fluid (n = 131), or urine (n = 173) specimens. Median bacterial load (TTP in days) was the strongest associate of MTB/RIF positivity in each fluid. TTP correlated with C(T) values in pulmonary specimens but not extrapulmonary specimens (Spearman's coefficient 0.5043 versus 0.1437; p = 0.030). Inhibition affected a greater proportion of pulmonary specimens than extrapulmonary specimens (IPC C(T) > 34: 6% (47/731) versus 1% (4/381; p < 0.0001). Pulmonary specimens had greater load than extrapulmonary specimens [TTPs (interquartile range) of 11 (7-16) versus 22 (18-33.5) days; p < 0.0001]. HIV-infection was associated with a decreased likelihood of MTB/RIF-positivity in pulmonary specimens but an increased likelihood in extrapulmonary specimens. Mycobacterial load, which displays significant variation across different body compartments, is the main determinant of MTB/RIF-positivity rather than PCR inhibition. MTB/RIF C(T) is a poor surrogate of load in extrapulmonary specimens.
منابع مشابه
Performance evaluation of three commercial molecular assays for the detection of Mycobacterium tuberculosis from clinical specimens in a high TB-HIV-burden setting
BACKGROUND A major challenge faced by countries with a high burden of tuberculosis (TB) is early detection especially in individuals with paucibacillary disease which is common in HIV endemic settings. Remarkable efforts have been made globally to accelerate the development and expansion of new diagnostic technologies that allow better and earlier diagnosis of active tuberculosis particularly d...
متن کاملPerformance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting
Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected ...
متن کاملA Comprehensive Evaluation of Xpert MTB/RIF Assay With Bronchoalveolar Lavage Fluid as a Single Test or Combined With Conventional Assays for Diagnosis of Pulmonary Tuberculosis in China: A Two-Center Prospective Study
Introduction: The Xpert MTB/RIF is recommended by the World Health Organization as a first line rapid test for the diagnosis of pulmonary tuberculosis (TB); however, China does not routinely use this test, partially due to the lack of a sufficient number of systematic evaluations of this assay in local patients. The aims of this study were to comprehensively assess the diagnostic performance of...
متن کاملDetection of Mycobacterium tuberculosis (MTB) in Fecal Specimens From Adults Diagnosed With Pulmonary Tuberculosis Using the Xpert MTB/Rifampicin Test
Background. The Xpert Mycobacterium tuberculosis (MTB)/rifampicin (RIF) is a fully automated diagnostic test that allows for the detection of MTB including its RIF resistance. Although the test is used for the diagnosis of tuberculosis (TB) in sputum samples worldwide, studies using fecal specimens are scarce. We therefore evaluated the efficacy of the Xpert MTB/RIF test for detection of MTB i...
متن کاملRapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country
OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2014