Interrelations of lead levels in bone, venous blood, and umbilical cord blood with exogenous lead exposure through maternal plasma lead in peripartum women.
نویسندگان
چکیده
Recent research has raised the possibility that fetal lead exposure is not estimated adequately by measuring lead content in maternal whole blood lead because of the variable partitioning of lead in whole blood between plasma and red blood cells. Lead in maternal plasma may derive in large part from maternal bone lead stores. In this study we aimed to estimate the contribution of maternal whole blood lead, maternal bone lead levels, and environmental lead to umbilical cord blood lead levels (as a measure of fetal lead exposure). In the model, we assumed that lead from all of these sources reaches the fetus through the maternal plasma lead pathway. In 1994-1995, we recruited 615 pregnant women for a study of lead exposure and reproductive outcomes in Mexico City. We gathered maternal and umbilical cord blood samples within 12 hr of each infant's delivery and measured maternal lead levels in cortical bone and trabecular bone by a K-X-ray fluorescence (K-XRF) instrument within 1 month after delivery. We administered a questionnaire to assess use of lead-glazed ceramics (LGC) to cook food and we obtained data on regional air lead levels during the 2 months before delivery. We used structural equation models (SEMs) to estimate plasma lead as the unmeasured (latent) variable and to quantify the interrelations of plasma lead, the other lead biomarkers, and environmental lead exposure. In the SEM analysis, a model that allowed plasma lead to vary freely from whole blood lead explained the variance of cord blood lead (as reflected by a total model R(2); R(2) = 0.79) better than did a model without plasma lead (r(2) = 0.67). Cortical bone lead, trabecular bone lead, use of LGC, and mean air lead level contributed significantly to plasma lead. The exchange of lead between plasma and red blood cells was mostly in the direction of plasma to cells. According to the final model, an increase in trabecular bone lead and cortical bone lead was associated with increases in cord blood lead of 0.65 and 0.25 microg/dL, respectively. An increase of 0.1 microg/m(3) in air lead was associated with an increase in the mean level of fetal cord blood lead by 0.67 microg/dL. With one additional day of LCG use per week in the peripartum period, the mean fetal blood lead level increased by 0.27 microg/dL. Our analyses suggested that maternal plasma lead varies independently from maternal whole blood lead and that the greatest influences on maternal plasma lead are maternal bone lead stores, air lead exposures, and recent cooking with LGC. The contributions from endogenous (bone) and exogenous (environmental) sources were relatively equal. Measurement of plasma and bone lead may be important in accurately assessing fetal lead exposure and its major sources, particularly if exogenous exposures decline.
منابع مشابه
Correlation between Lead in Maternal Blood, Umbilical Cord Blood, and Breast Milk with Newborn Anthro-pometric Characteristics
Background: Breast milk can be a source of toxic material, along with the transfer of nutrients needed for infant growth. This study was conducted to measure the level of lead in maternal and neonatal blood and breast milk in Tehran, Iran.Methods: In this cross-sectional study, 150 mothers and their infants were studied. Samples of maternal blood, fetal umbilical cord blood, breast milk, ...
متن کاملComparison of Maternal Serum and Umbilical Cord Blood Leptin Level in IUGR Neonates
Background: Gestational weight gain is an impressive factor in the fetal outcome. Intrauterine growth restriction (IUGR) is one of the most important problems during fetal period that may lead to many perinatal and long-term complications and growing neonatal morbidities and mortalities. The aim of the study was to ascertain the relationship between umbilical cord blood leptin concentration and...
متن کاملFetal Lead Exposure at Each Stage of Pregnancy as a Predictor of Infant Mental Development
BACKGROUND The impact of prenatal lead exposure on neurodevelopment remains unclear in terms of consistency, the trimester of greatest vulnerability, and the best method for estimating fetal lead exposure. OBJECTIVE We studied prenatal lead exposure's impact on neurodevelopment using repeated measures of fetal dose as reflected by maternal whole blood and plasma lead levels. METHODS We meas...
متن کاملLevels of lead in breast milk and their relation to maternal blood and bone lead levels at one month postpartum.
Despite the many well-recognized benefits of breast-feeding for both mothers and infants, detectable levels of lead in breast milk have been documented in population studies of women with no current environmental or occupational exposures. Mobilization of maternal bone lead stores has been suggested as a potential endogenous source of lead in breast milk. We measured lead in breast milk to quan...
متن کامل[Lead levels in pregnant women and newborns in la Oroya City, Peru].
OBJECTIVES To determine blood-lead (Pb) levels in pregnant women and neonates in a metallurgical city of Peru. MATERIALS AND METHODS A cross-sectional study was carried out, the population of which consisted of pregnant women who had lived for at least two years in the city of La Oroya, at the time when the lead, copper and zinc foundries operated normally. A blood sample was obtained from th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Environmental Health Perspectives
دوره 109 شماره
صفحات -
تاریخ انتشار 2001