Comparative performance of a panel of commercially available antimicrobial nanocoatings in Europe

نویسندگان

  • Johan W Molling
  • Jacques W Seezink
  • Birgit EJ Teunissen
  • Inhua Muijrers-Chen
  • Paul JA Borm
چکیده

BACKGROUND Bacterial resistance against the classic antibiotics is posing an increasing challenge for the prevention and treatment of infections in health care environments. The introduction of antimicrobial nanocoatings with active ingredients provides alternative measures for active killing of microorganisms, through a preventive hygiene approach. PURPOSE The purpose of this study was to investigate the antimicrobial activity of a panel of antimicrobial coatings available on the European market. METHODS A comparative, biased selection of commercially available antimicrobial coatings was tested for antimicrobial efficiency. Suppliers were contacted to deliver their coatings on glass and/or stainless steel substrates. In total, 23 coatings from eleven suppliers were received, which were investigated for their effect on the growth of Escherichia coli, using the International Organization for Standardization (ISO) 22196 protocol. RESULTS The majority of nanomaterial-containing coatings (n=13) contained nanosilver (n=12), while only one had photocatalytic TiO2 as the active particle. The differences in antimicrobial activity among all of the coatings, expressed as log reduction values, varied between 1.3 and 6.6, while the variation within the nanomaterial-based group was between 2.0 and 6.2. Although nanosilver coatings were on average very effective in reducing the number of viable bacteria after challenge, the strongest log reduction (6.6) was seen with a coating that has immobilized, covalently bound quaternary ammonium salt in its matrix. Besides these two compounds, coatings containing TiO2, poly(dimethylsiloxane), triclosan, or zinc pyrithione evoked 100% killing of E. coli. CONCLUSION Our findings indicate that nanosilver dominates the nanoparticle-based coatings and performs adequately. However, considering the unknowns in relation to ecotoxicological emission and effects, it needs further consideration before widespread application into different environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick

Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...

متن کامل

Evaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study

Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...

متن کامل

A comparative study for quality of local and imported commercially available bottled water brands

 In this study the quality of Omani and United Arab Emirates bottled water brands which are sold in Oman were assessed by comparing the chemical composition indicated on manufacturer’s label with local and international bottled water standards. Results indicated that all the bottled water brands are complying with local and international standards. According to piper diagram, t...

متن کامل

Photostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran

Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...

متن کامل

Photostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran

Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014