Performance Comparison of R-502 Replacements in a Commercial Scale Low Temperature Refrigeration Plant with a Two Stage Compressor

نویسندگان

  • P. F. Hearty
  • J. W. Linton
  • W. K. Snelson
چکیده

An existing commercial scale low temperature R-502 refrigeration plant has been extensively instrumented for evaluating R-502 long term replacements R-404A, R-407A and R-507. This installation is part of the refrigeration plant located at the Thermal Technology Centre. The R-502 retrofit test facility has an internally compounded two stage 40 HP reciprocating compressor equipped with desuperheating and subcooling. The evaporator used was a standard direct expansion shell and tube heat exchanger with R-502 on the tube side, and R-11 (used as a brine) on the shell side. The condenser was also a shell and tube heat exchanger with R-502 on the shell side and water on the tube side. A series of performance tests were carried out under controlled conditions at two different condensing temperatures: 40.6°C (105.0°F) and 29.4°C (85.0°F). The refrigerant evaporating temperature was varied over a range of -45.0°C to -25.0°C (-49.0°Fto -13.0°F). Test data were used to compare important system performance characteristics with R-502 including evaporator capacity, cooling coefficient of performance (COP), and compressor discharge temperature. A comparison of system operating refrigerant pressure drops and refrigerant mass flowrates is also included.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Azeotrope of HFC-125 and HFC-143a as an Alternative for R-502

R-502 has been the primary refrigerant for low temperature commercial refrigeration applications for many years. The impending phase-out of CFCs dictates its elimination in the very near future. The identification of alternative(s) for R-502 therefore becomes a high priority. This paper addresses the factors to be evaluated in selecting the best replacement and identifies an azeotropic mixture ...

متن کامل

System Performance of Some Long Term R-502 Replacements

A series of tests has been completed comparing the system performance of four long term replacements HP62 (44% R~125/ 54% R-143a/ 4% R-134a), AZ-50 (50% R-125/ 50% R-143a), Klea 60 (20% R-32/ 40% R-125/ 40% R-134a), and Klea 61 (1 0% R-32/ 70% R-125/ 20% R-134a) as potential alternatives for the CFC-containing low temperature refrigerant R-502. The tests were carried out under controlled condit...

متن کامل

Performance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger

In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...

متن کامل

Exergy, exergoeconomic and exergoenvironmental studies and optimization of a novel triple-evaporator refrigeration cycle with dual-nozzle ejector using low GWP refrigerants

In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the no...

متن کامل

Improvement of simple and regenerative gas turbine using simple and ejector-absorption refrigeration

The exhaust gases of gas turbine power plant carry a significant amount of thermal energy that is usually expelled to the atmosphere this causes a reduction in net work and efficiency of gas turbine. On the other hand, the generated power and efficiency of gas turbine plants depend largely on the temperature of the inlet air, So that they both increase as the inlet air temperature decreases. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014