Iterative image reconstruction techniques: Applications for cardiac CT.

نویسندگان

  • Matthias Renker
  • Ashok Ramachandra
  • U Joseph Schoepf
  • Rainer Raupach
  • Paul Apfaltrer
  • Garrett W Rowe
  • Sebastian Vogt
  • Thomas G Flohr
  • J Matthias Kerl
  • Ralf W Bauer
  • Christian Fink
  • Thomas Henzler
چکیده

BACKGROUND Traditional limitations of cardiac CT are related to image noise, blooming artifacts from calcifications and stents, and radiation exposure. We evaluated whether these limitations can be ameliorated by the use of iterative reconstruction in image space (IRIS) instead of traditional filtered back projection (FBP) image reconstruction techniques. METHODS We compared image reconstruction with the use of IRIS with traditional FBP for their effect on image quality, noise, volume of heavy coronary artery calcifications, and stents as a measure of "blooming" artifacts, and radiation dose at cardiac CT. The radiation dose comparison was performed as a matched pair analysis, whereas all other comparisons were performed within the same group of patients. RESULTS The subjective image quality of IRIS reconstructions was rated higher than FBP reconstructions. Image noise was lower with IRIS than with FBP. The volume of stents and heavy coronary artery calcifications measured lower in IRIS reconstructed series compared with FBP. Similar levels of image noise were achieved with 80/100 kVp of tube voltage with IRIS compared with 120 kVp and FBP, resulting in a 62% reduction in effective dose. CONCLUSION Our preliminary experiences suggest that IRIS incrementally improves the CT evaluation of coronary arteries, especially in challenging scenarios. Substantial radiation reduction seems feasible without associated increases in image noise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Medical Physics International

Computed tomography (CT) is a well stablished imaging technique that is used worldwide for diagnosis and treatment planning. The purpose of this review is to describe the most notable technological advances in the last decade, with a special focus on their impact in CT dose optimization, that is, achieving the same diagnostic image quality at a reduced radiation dose. The review describes main ...

متن کامل

Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.

PURPOSE To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patien...

متن کامل

Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome these challenges, we propose and compare improvements on two strategies for c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular computed tomography

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2011