Foramen Magnum Dural Arteriovenous Fistula Treated by a Microsurgical Technique Combined with a Feeder Occlusion Using Transarterial Coil Embolization.

نویسندگان

  • Ryo Hiramatsu
  • Terumasa Kuroiwa
  • Kazuhiko Nozaki
  • Toshihiko Kuroiwa
چکیده

The treatment of dural arteriovenous fistulas (DAVFs) at the foramen magnum remains controversial by reason that DAVFs appearing from the foramen magnum represent only a minority of spinal DAVFs. We present our treatment for an asymptomatic patient suffering from a foramen magnum DAVF. A 53-year-old man presented to our hospital with the complaint of a floating sensation. Although there was no subarachnoid hemorrhage or cerebral infarction on magnetic resonance imaging, a magnetic resonance angiography revealed a number of dilated veins and a large varix surrounding the medulla oblongata. Cerebral digital subtraction angiography (DSA) showed a foramen magnum DAVF fed by the neuromeningeal branch of the left ascending pharyngeal artery and occipital artery, draining into the posterior spinal vein. Occlusion of the fistula was achieved by a microsurgical technique combined with a feeder occlusion using transarterial coil embolization, without complications. We verified the complete occlusion on post-operative cerebral DSA. While this combined therapy was already established for the treatment of DAVFs, there were no reports of the combined therapy for foramen magnum DAVFs. This treatment was considered to be useful for foramen magnum DAVFs, especially those DAVFs at the foramen magnum with a number of dilated veins and a large varix.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular Treatment of Dural Arteriovenous Fistulas of the Transverse and Sigmoid Sinuses Using Transarterial Balloon-Assisted Embolization Combined with Transvenous Balloon Protection of the Venous Sinus.

BACKGROUND AND PURPOSE Combined transarterial balloon-assisted endovascular embolization with double-lumen balloon microcatheters and concomitant transvenous balloon protection was described as a promising treatment technique for dural arteriovenous fistulae of the transverse and sigmoid sinus. The purpose of this study was to evaluate the technical efficacy and safety of this combined treatmen...

متن کامل

Onyx transarterial embolization of dural arteriovenous fistula for failed N-butyl cyanoacrylate treatment: case report

Total occlusion of dural arteriovenous fistulas (DAVFs) via transarterial embolization is difficult due to the rich anastomotic network of the dural/falcine plethora of feeding arteries, blood supply to cranial nerves, and extracranial to intracranial anastomoses. Incomplete occlusion of the fistulas will result in recanalization of the DAVF from the multiple collateral arteries constituting th...

متن کامل

Tentorial Dural Arteriovenous Fistula Treated Using Transarterial Onyx Embolization

Tentorial dural arteriovenous fistula (DAVF) is a rare vascular disease, which has high risk of intracranial hemorrhage. We present two cases of tentorial DAVF which were successfully treated with single trial of transarterial embolization using Onyx. We briefly reviewed the types of the tentorial DAVF and strategies of treatment.

متن کامل

Transarterial coil embolization of the venous component of aggressive type 4 dural arteriovenous fistulas.

We report 2 patients with aggressive intracranial dural arteriovenous fistulae that were repaired via percutaneous, transarterial coil embolization of the venous outlets.

متن کامل

Endovascular treatment of dural sinus malformation with arteriovenous shunt in a low birth weight neonate--case report.

A boy was born at 36 weeks gestation weighing 2,135 g, with a prenatal diagnosis of dural sinus malformation with arteriovenous shunts. Congestive heart failure and anuria at birth prompted emergency intervention. Transfemoral-transvenous coil embolization was performed on day 1, resulting in partial occlusion of the huge venous pouch with a total length of 2,355 cm of detachable coils. Transar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2015