BACKGROUND To inform cost-effective decisions in purchasing new medical liquid crystal displays, we compared the image quality in displays made by three manufacturers. METHODS We recruited 19 radiologists and residents to compare the image quality of four liquid crystal displays, including 3-megapixel Barco(®), Eizo(®), and NEC(®) displays and a 6-megapixel Barco display. The evaluators were blinded to the manufacturers' names. Technical assessments were based on acceptance criteria and test patterns proposed by the American Association of Physicists in Medicine. Radiological assessments were performed on images from the American Association of Physicists in Medicine Task Group 18. They included X-ray images of the thorax, knee, and breast, a computed tomographic image of the thorax, and a magnetic resonance image of the brain. Image quality was scored on an analog scale (range 0-10). Statistical analysis was performed with repeated-measures analysis of variance. RESULTS The Barco 3-megapixel display passed all acceptance criteria. The Eizo and NEC displays passed the acceptance criteria, except for the darkest pixel value in the grayscale display function. The Barco 6-megapixel display failed criteria for the maximum luminance response and the veiling glare. Mean radiological assessment scores were 7.8±1.1 (Barco 3-megapixel), 7.8±1.2 (Eizo), 8.1±1.0 (NEC), and 8.1±1.0 (Barco 6-megapixel). No significant differences were found between displays. CONCLUSION According to the tested criteria, all the displays had comparable image quality; however, there was a three-fold difference in price between the most and least expensive displays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems.

Display systems are key components of the digital radiology department. Current display systems for medical imaging are based on cathode-ray tubes (CRTs) or active-matrix liquid crystal displays (AMLCDs). The CRT is a cathodoluminescent display: Light is generated by exciting a luminescent material with energetic electrons. AMLCDs are light-modulating devices that form the image in the screen b...

متن کامل

Image Stitching of the Computed Radiology images Using a Pixel-Based Approach

In this paper, a method for automatic stitching of radiology images based on pixel features has been presented. In this method, according to the smooth texture of radiological images and in order to increase the number of the extracted features after quality enhancement of initial radiology images, 45 degree isotropic mask is applied to each radiology image to observe the image details. After t...

متن کامل

Medical imaging displays and their use in image interpretation.

The adequate and repeatable performance of the image display system is a key element of information technology platforms in a modern radiology department. However, despite the wide availability of high-end computing platforms and advanced color and gray-scale monitors, the quality and properties of the final displayed medical image may often be inadequate for diagnostic purposes if the displays...

متن کامل

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014