Inverted ILM flap, free ILM flap and conventional ILM peeling for large macular holes
نویسندگان
چکیده
Background To assess closure rate after a single surgery of large macular holes and their visual recovery in the short term with three different surgical techniques. Methods Prospective multicenter randomized controlled trial. We included treatment-naïve patients with diagnosis of large macular hole (minimum diameter of > 400 µm). All patients underwent a comprehensive ophthalmological examination. Before surgery, the patients were randomized into three groups: group A: conventional internal limiting membrane peeling, group B: inverted-flap technique and group C: free-flap technique. All study measurements were repeated within the period of 1 and 3 months after surgery. Continuous variables were assessed with a Kruskal-Wallis test, change in visual acuity was assessed with analysis of variance for repeated measurements with a Bonferroni correction for statistical significance. Results Thirty-eight patients were enrolled (group A: 12, group B: 12, group C: 14). The closure rate was in group A and B: 91.6%; 95% CI 61.52-99.79%. In group C: 85.71%; 95% CI 57.19-98.22%. There were no differences in the macular hole closure rate between groups (p = 0.85). All groups improved ≈ 0.2 logMAR, but only group B reached statistical significance (p < 0.007). Conclusions Despite all techniques displayed a trend toward visual improvement, the inverted-flap technique seems to induce a faster and more significant recovery in the short term.
منابع مشابه
Comparison of the Inverted Internal Limiting Membrane Flap Technique and the Internal Limiting Membrane Peeling for Macular Hole with Retinal Detachment
PURPOSE To evaluate the efficacy of the inverted internal limiting membrane (ILM) flap technique in vitrectomy for macular hole (MH) with retinal detachment (RD) compared with vitrectomy using ILM peeling. METHODS A retrospective case series study was performed. Twenty-two eyes of 22 patients who underwent vitrectomy for MH with RD and followed-up more than 12 months after the surgery were in...
متن کاملInternal Limiting Membrane Closure of Idiopathic Macular Hole
Purpose: To evaluate the efficacy and safety of combined phacoemulsification and 23gauge pars plana vitrectomy with Brilliant blue-G (BBG)-assisted ILM peeling in idiopathic macular hole surgery with closure of the hole by an inverted ILM flap. Design: Prospective and interventional case series. Methods: 23 eyes with large (>400 μm) idiopathic macular hole treated by phacoemulsification with po...
متن کاملVitrectomy with internal limiting membrane peeling versus inverted internal limiting membrane flap technique for macular hole-induced retinal detachment: a systematic review of literature and meta-analysis
BACKGROUND To evaluate the effects on vitrectomy with internal limiting membrane (ILM) peeling versus vitrectomy with inverted internal limiting membrane flap technique for macular hole-induced retinal detachment (MHRD). METHODS Pubmed, Cochrane Library, and Embase were systematically searched for studies that compared ILM peeling with inverted ILM flap technique for macular hole-induced reti...
متن کاملThe Expansion of RPE Atrophy after the Inverted ILM Flap Technique for a Chronic Large Macular Hole
PURPOSE To report a case of the expansion of submacular retinal pigment epithelium (RPE) atrophy after using the inverted internal limiting membrane (ILM) flap technique for a persisting, large, stage IV macular hole (MH). CASE REPORT A 79-year-old woman presented with a chronic large MH that remained open despite pars plana vitrectomy (PPV). The surgery was performed twice for the MH closure...
متن کاملIs it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
BACKGROUND To report a case of late closure of idiopathic full-thickness macular hole (FTMH) after vitrectomy with the inverted internal limiting membrane (ILM) technique. CASE PRESENTATION A 68-year-old lady with a stage IV FTMH underwent pars plana vitrectomy with 25 gauge plus transconjunctival system, ILM peeling and gas tamponade. The inverted ILM flap technique was adopted, except that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2018