Hosting the Unwanted: Stethoscope Contamination Threat

نویسندگان

  • Gabriele Messina
  • Emma Ceriale
  • Sandra Burgassi
  • Carmela Russo
  • Nicola Nante
  • Lorenzo Mariani
  • Lucilla Taddei
  • Daniele Lenzi
  • Pietro Manzi
چکیده

Aims: Stethoscopes represent a vehicle of bacteria and other microorganisms and may play a role in the spread of health-care associated infections (HAIs). We aimed to evaluate the contamination levels of stethoscopes before and after use of a disinfecting technique (DT). Original Research Article British Journal of Medicine & Medical Research, 4(30): 4868-4878, 2014 4869 Study Design: Matched cross-over study. Place and Duration of Study: The study was conducted in July 2012 and involved three hospitals in Siena Province (Italy). Two were public hospitals with about 750 and 140 beds, and the other was private with 40 beds. Methodology: We evaluated: i) contamination on 74 shared and non shared stethoscopes; ii) bacterial load before and after use of a DT. Total bacterial count (TBC) at 36oC and 22oC, Staphylococcus spp., molds, Enterococcus spp., Pseudomonas spp., Escherichia coli and total coliforms bacteria were evaluated. Mann Whitney and Wilcoxon tests were used for comparisons (p<0.05). Results: Before DT, 49 stethoscopes were positive for TBC at 36oC, 48 for TBC at 22oC, 40 for Staphylococcus spp., 18 for methicillin-resistant Staphylococcus aureus, 33 for coliforms (9 for Escherichia coli), 5 for Enterococcus spp. and 2 for molds. After cleaning, the percentage reduction in CFUs was close at 100% in most comparisons. Shared stethoscopes proved to be less contaminated than non shared ones (p<0.05). Conclusion: Our results suggest that stethoscopes may be potential vehicles of HAIs. The DT was effective in reducing bacterial contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of stethoscope contamination following a standardized physical exam

Methods Following a standardized physical exam using sterile gloves and a sterile stethoscope, bacterial contamination of the following regions were assessed using contact plates: stethoscope diaphragm, stethoscope tube, fingertips, thenar region, hypothenar region and back of physician’s dominant hand. Total aerobic colony count (ACC) were determined on digital photographs using a counting tool.

متن کامل

Contamination Level of Stethoscopes Used By Physicians and Physician Assistants

The Journal of Physician Assistant Education | 2007 Vol 18 No 2 INTRODUCTION The stethoscope is a popular instrument used by health care providers to evaluate the lung, heart, and abdominal sounds of their patients. Although clinicians are instructed about microbiology and the importance of maintaining clean medical instruments, the stethoscope may not be thought of as a potential source of nos...

متن کامل

Bacterial contamination of stethoscopes with antimicrobial diaphragm covers.

Antimicrobial stethoscope covers impregnated with silver ions have been developed to prevent surface contamination and potential transmission of bacterial pathogens to patients. To test their practical utility, covers were distributed with the manufacturers' recommendations to a mixed group of health care professionals in a medical/surgical intensive care unit and an emergency department. Seven...

متن کامل

Stethoscope disinfection campaign in a Nigerian teaching hospital:results of a before-and-after study.

INTRODUCTION This study aimed to assess the impact of a stethoscope disinfection sensitization campaign among doctors and nurses in a Nigerian teaching hospital. METHODOLOGY The design was a before-and-after study. Pre-program measurements were used to provide a baseline against which the post-program results were compared. Interventions that promoted compliance with stethoscope disinfection ...

متن کامل

The stethoscope as a potential source of transmission of bacteria.

To the Editor: Contamination of stethoscopes by skin flora has been described previously. 1 The predominant organisms recovered from stethoscope diaphragms were Staphylococcus epider-midis and Staphylococcus aureus. Previous studies documented the status of contamination of the stethoscope diaphragm with microorganisms only once, and no repeat sampling was performed. 1 The dynamic of contaminat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014