Typically microgrid is composed of Distributed Generators (DGs), storage devices and loads which can be operated in grid-connected or islanding mode. Microgrid brings merits to both suppliers and consumers; hence, there would be a lot of microgrids at the distribution level with different load curves and DG types in near future interchanging their surplus/shortage of supply with each other or the utility grid. Upon inception of a fault in an individual macrogrid, it would be disconnected from the utility grid and operates in an autonomous mode. For the microgrids with all inverter-based DGs, the frequency maybe considerably deviated from the nominal value upon disconnection from the utility-grid; that is impermissible for consumers. In this paper, the interconnection of two adjacent inverter-based microgrids with different frequencies is proposed, using Back to Back Voltage-Sourced Converters (BTB VSCs) with local controllers in order to maintain the frequency in emergencies. By application of the proposed algorithm, two microgrids could play the role of an auxiliary supply/demand for each other without the necessity of implementing a communication link between the two microgrids. Simulation results show that the BTB VSCs with the proposed control strategy can effectively improve the frequency control task of the two microgrids simultaneously. 2015 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suggested New Voltage and Frequency Control Framework for Autonomous Operation of Microgrids

Decentralized control strategies are popular candidates in microgrids control because of their reliability and performance. Conventionally, droop control (as a main decentralized strategy) is been utilized in order to prevent permanent droop of voltage and frequency after change in loads and also to share generated power between distributed generation units. In this paper, a new droop control s...

متن کامل

An Efficient Strategy for Power Rating Reduction of Back-to-Back Converters Used in Railway Power Conditioner

One of the most common solutions to deal with the power quality issues of electrical railway systems is employing Railway Power Conditioner (RPC). In the conventional mode of operation, the RPC power rating deployed in every Traction Power Substation (TPS) is significantly large. This paper mainly focuses on the power rating reduction of RPC through presenting a novel combinatorial compensation...

متن کامل

Effect of Distributed Energy Resources in Energy Hubs on Load and Loss Factors of Energy Distribution Networks

In this paper, an attempt has been made to introduce a new control strategy including Plug-in Hybrid Electric Vehicle (PHEV) and Diesel engine generator to control the voltage and frequency of autonomous microgrids. The proposed control strategy has multiple advantages over the recent control methods in microgrids. The proposed method applies the primary and secondary frequency control strategy...

متن کامل

On The Analytical Tuning Of Controllers for Grid-Coupled Voltage Source Converter: Frequency Analysis

The grid conditions determine what the output voltage of a grid connected power converters should be. Control of the output voltage of these power converters is by this condition not possible. The power converters are however, not directly connected to the grid. The conventional method to interface these converters to the grid is through filters [1,2]. The duty of the filter is to reduce the cu...

متن کامل

On The Analytical Tuning Of Controllers for Grid-Coupled Voltage Source Converter: Frequency Analysis

The grid conditions determine what the output voltage of a grid connected power converters should be. Control of the output voltage of these power converters is by this condition not possible. The power converters are however, not directly connected to the grid. The conventional method to interface these converters to the grid is through filters [1,2]. The duty of the filter is to reduce the cu...

متن کامل