Installation of a Neuromate Robot for Stereotactic Surgery: Efforts to Conform to Japanese Specifications and an Approach for Clinical Use—Technical Notes

نویسندگان

  • Yasukazu KAJITA
  • Daisuke NAKATSUBO
  • Hirotada KATAOKA
  • Toshiya NAGAI
  • Takahiro NAKURA
  • Toshihiko WAKABAYASHI
چکیده

The neuromate is a commercially available, image-guided robotic system for use in stereotactic surgery and is employed in Europe and North America. In June 2015, this device was approved in accordance with the Pharmaceutical Affairs Law in Japan. The neuromate can be specified to a wide range of stereotactic procedures in Japan. The stereotactic X-ray system, developed by a Japanese manufacturer, is normally attached to the operating table that provides lateral and anteroposterior images to verify the positions of the recording electrodes. The neuromate is designed to be used with the patient in the supine position on a flat operating table. In Japan, deep brain stimulation surgery is widely performed with the patient's head positioned upward so as to minimize cerebrospinal fluid leakage. The robot base where the patient's head is fixed has an adaptation for a tilted head position (by 25 degrees) to accommodate the operating table at proper angle to hold the patient's upper body. After these modifications, the accuracy of neuromate localization was examined on a computed tomography phantom preparation, showing that the root mean square error was 0.12 ± 0.10 mm. In our hospital, robotic surgeries, such as those using the Da Vinci system or neuromate, require operative guidelines directed by the Medical Risk Management Office and Biomedical Research and Innovation Office. These guidelines include directions for use, procedural manuals, and training courses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems.

The NeuroMatetrade mark robot system (Integrated Surgical Systems, Davis, CA) is a commercially available, image-guided, robotic-assisted system used for stereotactic procedures in neurosurgery. In this article, we present a quantitative comparison of the application accuracy of the NeuroMate with that of standard frame-based and frameless stereotactic techniques. The article discusses a five-w...

متن کامل

Principles of Neuronavigation

Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...

متن کامل

Investigation on the Effect of Different Parameters in Wheeled Mobile Robot Error (TECHNICAL NOTE)

This article has focused on evaluation and identification of effective parameters in positioning performance with an odometry approach of an omni-directional mobile robot. Although there has been research in this field, but in this paper, a new approach has been proposed for mobile robot in positioning performance. With respect to experimental investigations of different parameters in omni-dire...

متن کامل

Dual Space Control of a Deployable Cable Driven Robot: Wave Based Approach

Known for their lower costs and numerous applications, cable robots are an attractive research field in robotic community. However, considering the fact that they require an accurate installation procedure and calibration routine, they have not yet found their true place in real-world applications. This paper aims to propose a new controller strategy that requires no meticulous calibration and ...

متن کامل

Improvement of position measurement for 6R robot using magnetic encoder AS5045

Recording the variation of joint angles as a feedback to the control unit is frequent in articulated arms. In this paper, magnetic sensor AS5045, which is a contactless encoder, is employed to measure joint angles of 6R robot and the performance of that is examined. The sensor has a low volume, two digital outputs and provides a high resolution measurement for users; furthermore its zero positi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2015